Evidence map›Paper›PMID 25871432›Full record

ArticleMedical principles and practice : international journal of the Kuwait University, Health Science Centre2015

Utility of Tc-PEG4-E[PEG4-c(RGDfK)]2 in Posttherapy Surveillance of Patients with Reelevated Carcinoembryonic Antigen Levels.

Rui Gao, Guangjian Zhang, Ling Chen, Zhaohui Zhu, Fan Wang, Aimin Yang

Open access · diamondAbstract read
In one paragraph

Article in Medical principles and practice : international journal of the Kuwait University, Health Science Centre, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Effect of Electroacupuncture onScientific reports · 2018
    Article
  2. Clinical Value ofScientific reports · 2018
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 2 countries.

Rui GaoDepartment of Nuclear Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China.
Guangjian Zhang
Ling Chen
Zhaohui Zhu
Fan Wang
Aimin Yang
Chinese Academy of Medical Sciences & Peking Union Medical College · CNFirst Affiliated Hospital of Xi'an Jiaotong University · CNPeking University · CNThoracic Surgery Foundation · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate the efficacy of (99m)Tc-PEG4-E[PEG4-c (RGDfK)]2 ((99m)Tc-3PRGD2) single photon emission computed tomography (SPECT) in monitoring the recurrence of malignancies. MATERIALS AND

methods(99m)Tc-3PRGD2 SPECT was performed on 28 patients (10 females and 18 males; median age 49.2 years) suspected of recurrent malignancies due to an asymptomatically reelevated carcinoembryonic antigen level. The SPECT was performed 0.5 h after an intravenous injection of 11.1 MBq/kg (0.3 mCi/kg) of (99m)Tc-3PRGD2. The SPECT and concurrent contrast-enhanced computed tomography (ceCT) findings were analyzed with reference to the histopathological findings and/or clinical follow-up data.

resultsRecurrences were identified in 20 out of the 28 patients (prevalence 71.4%) with altogether 26 lesions. Fifteen lesions were confirmed by histopathological findings, and the other 11 lesions were confirmed by serial radiological or clinical follow-up. Of the 20 patients with recurrent malignancies, 12 (60%) were correctly identified by (99m)Tc-3PRGD2 SPECT. In the patient-based analysis, the sensitivity and specificity of (99m)Tc-3PRGD2 SPECT were 60 and 100%, respectively, and the positive and negative predictive values were 100 and 50%, respectively. In the lesion-based evaluation, the sensitivity and specificity were 62 and 100%, respectively. The sensitivity and specificity of the ceCT in the patient-based evaluation were 60 and 75%, respectively, and the positive and negative predictive values were 86 and 40%, respectively. In the lesion-based evaluation, the sensitivity and specificity of the ceCT were 70 and 84%, respectively.

conclusions(99m)Tc-3PRGD2, as a new SPECT tracer targeting the integrin αvβ3 receptor, was more useful in distinguishing recurrences as compared to ceCT.

Indexed as

Organotechnetium CompoundsAdultAgedCarcinoembryonic AntigenContrast MediaFemaleHumansMaleMiddle AgedNeoplasm MetastasisNeoplasm Recurrence, LocalNeoplasmsRadiographySensitivity and SpecificityTomography, Emission-Computed, Single-PhotonCarcinoembryonic AntigenContrast MediaOrganotechnetium Compounds

Identifiers

PMID25871432
PMCPMC5639622
OpenAlexW2070954790

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.