Multiharmonic electron paramagnetic resonance for extended samples with both narrow and broad lines.

Zhelin Yu, Mark Tseytlin, Sandra S Eaton, Gareth R Eaton

Open access · greenAbstract read
In one paragraph

Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.2field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 38 citations in OpenAlex.

  1. Review
  2. Article
  3. Have We Been Teaching Continuous Wave EPR Correctly?Journal of chemical education · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Rapid scan EPR: Automated digital resonator control for low-latency data acquisition.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2022
    Article
  8. Article
  9. General solution for rapid scan EPR deconvolution problem.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2020
    Article
  10. Rapid-scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017
    Review
  11. Field-stepped direct detection electron paramagnetic resonance.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Zhelin YuDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210, USA.
Mark TseytlinDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210, USA; Geisel School of Medicine, Dartmouth College, Hanover, NH 03755, USA.
Sandra S EatonDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210, USA.
Gareth R EatonDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210, USA. Electronic address: geaton@du.edu.
University of Denver · US

Funding

Preclinical Electron Paramagnetic Resonance Tumor ImagerR01CA177744 · NCI · UNIVERSITY OF DENVER (COLORADO SEMINARY) · PI EATON, GARETH R · 2014 to 2019
$2.7M
Enhancing in vivo EPR imaging using spin probes with short relaxation timesK25EB016040 · NIBIB · WEST VIRGINIA UNIVERSITY · PI TSEYTLIN, MARK · 2013 to 2015
$416k
NCI NIH HHS CA177744NCI NIH HHS R01 CA177744NIBIB NIH HHS K25 EB016040
6 · The paper itself

Abstract

Multiharmonic electron paramagnetic resonance spectroscopy was demonstrated for two samples with both narrow and broad lines: (i) α,γ-Bisdiphenylene-β-phenylallyl (BDPA) with ΔBpp of 0.85 G plus ultramarine blue with ΔBpp of 17 G, and (ii) a nitroxide radical immobilized in sucrose octaacetate. Modulation amplitudes up to 17 G at 41 kHz were generated with a rapid scan coil driver and Litz wire coils that provide uniform magnetic field sweeps over samples with heights of 5mm. Data were acquired with a 2-D experiment in the Xepr software through the transient signal path of a Bruker E500T and digitized in quadrature with a Bruker SpecJet II. Signals at the modulation frequency and its harmonics were calculated by digital phase-sensitive detection. The number of harmonics with signal intensity greater than noise increases as the ratio of the modulation amplitude to the narrowest peak increases. Spectra reconstructed by the multiharmonic method from data obtained with modulation amplitudes up to five times the peak-to-peak linewidths of the narrowest features have linewidths that are broadened by up to only about 10% relative to linewidths in spectra obtained at low modulation amplitudes. The signal-to-noise improves with increasing modulation amplitude up to the point where the modulation amplitude is slightly larger than the linewidth of the narrowest features. If this high a modulation amplitude had been used in conventional methodology the linewidth of the narrowest features would have been severely broadened. The multiharmonic reconstruction methodology means that the selection of the modulation amplitude that can be used without spectral distortion is no longer tightly tied to the linewidth of the narrowest line.

Indexed as

Aluminum SilicatesElectromagnetic FieldsElectron Spin Resonance SpectroscopyFree RadicalsIsotope LabelingNitrogen OxidesSoftwareSucroseAluminum SilicatesFree RadicalsNitrogen OxidesSucrosesucrose octaacetateultramarine (pigment)BDPADigital phase-sensitive detectionEPRMultiple harmonicsNitroxideOvermodulation

Identifiers

PMID25863892
PMCPMC4420703
OpenAlexW2006891064

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.