A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy.

Yuan Xu, Ti Bai, Hao Yan, Luo Ouyang, Arnold Pompos, Jing Wang, Linghong Zhou, Steve B Jiang, Xun Jia

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 48 papers.

0numbers the graph read from it
0cells of the map it votes in
48citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

48 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Improving CBCT image quality to the CT level using RegGAN in esophageal cancer adaptive radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2023
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Estimation of planning organ at risk volumes for ocular structures in dogs undergoing three-dimensional image-guided periocular radiotherapy with rigid bite block immobilization.Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yuan XuDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Ti BaiDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Hao YanDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Luo OuyangDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Arnold PomposDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Jing WangDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Linghong ZhouDepartment of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong 510515, People's Republic of China.
Steve B JiangDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.
Xun JiaDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA.

Funding

Low dose cone beam CT for image guided adaptive radiotherapyR01CA154747 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI JIANG, STEVE BIN · 2011 to 2015
$1.4M
4D cone beam CT reconstruction for radiotherapy via motion vector optimizationR21EB017978 · NIBIB · UT SOUTHWESTERN MEDICAL CENTER · PI JIA, XUN · 2014 to 2015
$444k
A progressive cone-beam CT dose control scheme for image-guided radiation therapyR21CA178787 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI JIA, XUN · 2014 to 2015
$380k
NCI NIH HHS 1R01CA154747-01NCI NIH HHS 1R21CA178787-01A1NCI NIH HHS R01 CA154747NCI NIH HHS R21 CA178787NIBIB NIH HHS 1R21EB017978-01A1NIBIB NIH HHS R21 EB017978
6 · The paper itself

Abstract

Cone-beam CT (CBCT) has become the standard image guidance tool for patient setup in image-guided radiation therapy. However, due to its large illumination field, scattered photons severely degrade its image quality. While kernel-based scatter correction methods have been used routinely in the clinic, it is still desirable to develop Monte Carlo (MC) simulation-based methods due to their accuracy. However, the high computational burden of the MC method has prevented routine clinical application. This paper reports our recent development of a practical method of MC-based scatter estimation and removal for CBCT. In contrast with conventional MC approaches that estimate scatter signals using a scatter-contaminated CBCT image, our method used a planning CT image for MC simulation, which has the advantages of accurate image intensity and absence of image truncation. In our method, the planning CT was first rigidly registered with the CBCT. Scatter signals were then estimated via MC simulation. After scatter signals were removed from the raw CBCT projections, a corrected CBCT image was reconstructed. The entire workflow was implemented on a GPU platform for high computational efficiency. Strategies such as projection denoising, CT image downsampling, and interpolation along the angular direction were employed to further enhance the calculation speed. We studied the impact of key parameters in the workflow on the resulting accuracy and efficiency, based on which the optimal parameter values were determined. Our method was evaluated in numerical simulation, phantom, and real patient cases. In the simulation cases, our method reduced mean HU errors from 44 to 3 HU and from 78 to 9 HU in the full-fan and the half-fan cases, respectively. In both the phantom and the patient cases, image artifacts caused by scatter, such as ring artifacts around the bowtie area, were reduced. With all the techniques employed, we achieved computation time of less than 30 s including the time for both the scatter estimation and CBCT reconstruction steps. The efficacy of our method and its high computational efficiency make our method attractive for clinical use.

Indexed as

SoftwareCone-Beam Computed TomographyMonte Carlo MethodRadiotherapy, Image-GuidedScattering, Radiation

Identifiers

PMID25860299
PMCPMC4409575

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.