Evidence map›Paper›PMID 25856094›Full record

ArticlePloS one2015

A computer-simulation study on the effects of MRI voxel dimensions on carotid plaque lipid-core and fibrous cap segmentation and stress modeling.

Harm A Nieuwstadt, Zaid A M Kassar, Aad van der Lugt, Marcel Breeuwer, Anton F W van der Steen, Jolanda J Wentzel, Frank J H Gijsen

Abstract read
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Harm A NieuwstadtDepartment of Biomedical Engineering, Erasmus MC, Rotterdam, the Netherlands.
Zaid A M KassarDepartment of Biomedical Engineering, Erasmus MC, Rotterdam, the Netherlands; Department of Radiology, Erasmus MC, Rotterdam, the Netherlands.
Aad van der LugtDepartment of Radiology, Erasmus MC, Rotterdam, the Netherlands.
Marcel BreeuwerPhilips Healthcare, Best, the Netherlands; Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands.
Anton F W van der SteenDepartment of Biomedical Engineering, Erasmus MC, Rotterdam, the Netherlands; Department of Imaging Science and Technology, Delft University of Technology, Delft, the Netherlands.
Jolanda J WentzelDepartment of Biomedical Engineering, Erasmus MC, Rotterdam, the Netherlands.
Frank J H GijsenDepartment of Biomedical Engineering, Erasmus MC, Rotterdam, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe benefits of a decreased slice thickness and/or in-plane voxel size in carotid MRI for atherosclerotic plaque component quantification accuracy and biomechanical peak cap stress analysis have not yet been investigated in detail because of practical limitations.

methodsIn order to provide a methodology that allows such an investigation in detail, numerical simulations of a T1-weighted, contrast-enhanced, 2D MRI sequence were employed. Both the slice thickness (2 mm, 1 mm, and 0.5 mm) and the in plane acquired voxel size (0.62x0.62 mm2 and 0.31x0.31 mm2) were varied. This virtual MRI approach was applied to 8 histology-based 3D patient carotid atherosclerotic plaque models.

resultsA decreased slice thickness did not result in major improvements in lumen, vessel wall, and lipid-rich necrotic core size measurements. At 0.62x0.62 mm2 in-plane, only a 0.5 mm slice thickness resulted in improved minimum fibrous cap thickness measurements (a 2-3 fold reduction in measurement error) and only marginally improved peak cap stress computations. Acquiring voxels of 0.31x0.31 mm2 in-plane, however, led to either similar or significantly larger improvements in plaque component quantification and computed peak cap stress.

conclusionsThis study provides evidence that for currently-used 2D carotid MRI protocols, a decreased slice thickness might not be more beneficial for plaque measurement accuracy than a decreased in-plane voxel size. The MRI simulations performed indicate that not a reduced slice thickness (i.e. more isotropic imaging), but the acquisition of anisotropic voxels with a relatively smaller in-plane voxel size could improve carotid plaque quantification and computed peak cap stress accuracy.

Indexed as

Models, CardiovascularAnisotropyCarotid ArteriesCarotid StenosisComputer SimulationHumansLipidsMagnetic Resonance ImagingPlaque, AtheroscleroticLipids

Identifiers

PMID25856094
PMCPMC4391711

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.