Evidence map›Paper›PMID 25855877›Full record

ArticleCanadian journal of gastroenterology & hepatology2015

Noninvasive methods, including transient elastography, for the detection of liver disease in adults with cystic fibrosis.

Matthew D Sadler, Pam Crotty, Linda Fatovich, Stephanie Wilson, Harvey R Rabin, Robert P Myers

Abstract read
In one paragraph

Article in Canadian journal of gastroenterology & hepatology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Guideline
  5. Trial
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review: Pathogenesis of cholestatic liver diseases.World journal of hepatology · 2020
    Review
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Matthew D Sadler
Pam Crotty
Linda Fatovich
Stephanie Wilson
Harvey R Rabin
Robert P Myers

Funding

Canadian Institutes of Health Research
6 · The paper itself

Abstract

backgroundLiver disease is the third leading cause of mortality in patients with cystic fibrosis (CF). However, detection of CF-associated liver disease (CFLD) is challenging.

objectiveTo evaluate the diagnostic performance of noninvasive methods for the detection of CFLD with a focus on transient elastography (TE).

methodsPatients at the Adult CF Clinic of Calgary and Southern Alberta (n=127) underwent liver stiffness measurement (LSM) by TE using the FibroScan (FS, Ecosens, France) M probe; aspartate aminotransferase to platelet ratio index (APRI) and FibroTest (FT) scores were also calculated. The diagnostic performance of these tools for the detection of CFLD (defined as two or more the following criteria: abnormal liver biochemistry, hepatomegaly or sonographic abnormalities other than steatosis) were compared using the area under ROC curves.

resultsForty-seven percent of the cohort was male. The median age was 27 years (interquartile range [IQR] 22 to 37 years) and body mass index 21 kg⁄m(2) (IQR 19 kg⁄m(2) to 23 kg⁄m(2)); 25% of patients were on ursodeoxycholic acid and 12% had undergone lung transplantation. The prevalence of CFLD was 14% (n=18). FS was successful in all patients; one (0.8%) patient had poorly reliable results (IQR⁄M >30% and LSM ≥7.1 kPa). Compared with patients without CFLD (n=109), individuals with CFLD had higher median LSM according to FS (3.9 kPa [IQR 3.4 to 4.9 kPa] versus 6.4 kPa [IQR 4.4 to 8.0 kPa]), APRI (0.24 [IQR 0.17 to 0.31] versus 0.50 [IQR 0.22 to 1.18]) and FT scores (0.08 [IQR 0.05 to 1.5] versus 0.18 [IQR 0.11 to 0.35]; all P<0.05). Area under ROC curve for FS, APRI and FT for the detection of CFLD were 0.78 (95% CI 0.65 to 0.92), 0.72 (95% CI 0.56 to 0.87) and 0.76 (95% CI 0.62 to 0.90) (P not significant). At a threshold of >5.2 kPa, the sensitivity, specificity, positive and negative predictive values of LSM according to FS for detecting CFLD were 67%, 83%, 40% and 94%, respectively.

conclusionsFS, APRI and FT were useful noninvasive methods for detecting CFLD in adults.

Indexed as

Elasticity Imaging TechniquesPlatelet CountAdultAlbertaAspartate AminotransferasesBiomarkersCohort StudiesCystic FibrosisFemaleHumansLiver DiseasesMalePredictive Value of TestsPrevalenceSensitivity and SpecificitySeverity of Illness IndexAspartate AminotransferasesBiomarkers

Identifiers

PMID25855877
PMCPMC4399373

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.