ArticleJournal of diabetes science and technology2015

How to Assess the Quality of Glucose Clamps? Evaluation of Clamps Performed With ClampArt, a Novel Automated Clamp Device.

Carsten Benesch, Tim Heise, Oliver Klein, Lutz Heinemann, Sabine Arnolds

Abstract readComparative StudyEvaluation Study
In one paragraph

Article in Journal of diabetes science and technology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Trial
  9. Precision and accuracy of hyperglycemic clamps in a multicenter study.American journal of physiology. Endocrinology and metabolism · 2021
    Trial
  10. Trial
  11. Trial
  12. Trial
  13. Trial
  14. Trial
  15. Trial
  16. Trial
  17. Trial
  18. Trial
  19. Trial
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Carsten BeneschProfil, Neuss, Germany.
Tim HeiseProfil, Neuss, Germany.
Oliver KleinProfil, Neuss, Germany.
Lutz HeinemannProfil, Neuss, Germany.
Sabine ArnoldsProfil, Neuss, Germany sabine.arnolds@profil.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThere are no widely accepted parameters to assess the quality of glucose clamps. Thus, we selected different parameters describing clamp quality. These parameters were then evaluated in glucose clamps carried out with ClampArt, a novel CE-marked, state-of-the-art fully automated glucose clamp device employing continuous blood glucose (BG) measurements and minute-by-minute adaptations of glucose infusion rate (GIR).

methodsThirty-nine glucose clamps were performed in 10 healthy and 29 subjects with type 1 diabetes (T1DM) (total duration 583 h). ClampArt-based BG measurements were compared with those obtained with a laboratory reference method. Clamp quality was assessed by 5 parameters: (1) difference (mg/dl) of all paired BG measurements of ClampArt versus reference method ("trueness"), (2) coefficient of variation (CV, %) of ClampArt's BG measurements at target clamp level ("precision"), (3) mean absolute relative difference (MARD, %) at target clamp level ("accuracy"), (4) difference (mg/dl) between ClampArt and target BG ("control deviation"), and (5) percentage operational time ("utility").

resultsClampArt-based BG measurements showed a trueness of 1.2 ± 2.5 mg/dl. CV and MARD at target BG were 5.5 ± 2.1% and 5.3 ± 2.3%, respectively. There were only small deviations from target level (1.2 ± 1.6 mg/dl). Operational time was as high as 95.4% ± 4.1% (means ± SD).

conclusionsThe selected parameters seem to be adequate to characterize clamp quality. The novel, fully automated clamp device ClampArt achieves high clamp quality, which in future trials should be compared with other (automated and manual) clamp methods.

Indexed as

Glucose Clamp TechniqueAdultAutomationBlood GlucoseDiabetes Mellitus, Type 1Equipment DesignFemaleHumansMaleMiddle AgedMonitoring, PhysiologicQuality of Health CareReproducibility of ResultsYoung AdultBlood GlucoseClampArtglucose clamppharmacodynamicstype 1 diabetes

Identifiers

PMID25852075
PMCPMC4525648

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.