Patient radiation dose reduction using an X-ray imaging noise reduction technology for cardiac angiography and intervention.

Shigeru Nakamura, Tomoko Kobayashi, Atsushi Funatsu, Tadahisa Okada, Maria Mauti, Yuki Waizumi, Shinichi Yamada

Registry-linked trialAbstract read
PubMed Publisher
In one paragraph

Article in Heart and vessels, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06944509 (RADIQAL Study), which is not on this map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06944509 naactive not recruitingnot on this mapstarted 2025, after this paper: background citation

RADIQAL Study (Radiation Dose and Image Quality Trial)

TypeinterventionalSponsorPhilips Clinical & Medical Affairs GlobalRan2025 to 2027Enrolled824ConditionsCoronary Artery DiseaseArmstreatment with the Azurion system with Xres5, Azurion with Clairy IQ
3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. Article
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Impact of new X-ray technology on patient dose in pacemaker and implantable cardioverter defibrillator (ICD) implantations.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2017
    Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shigeru NakamuraKyoto-Katsura Hospital, 17-banchi, Yamada Hirao-cho, Nishikyo-ku, Kyoto-shi, Kyoto, Zip 6158256, Japan. kcvc.nakamura@katsura.com.
Tomoko KobayashiKyoto-Katsura Hospital, 17-banchi, Yamada Hirao-cho, Nishikyo-ku, Kyoto-shi, Kyoto, Zip 6158256, Japan.
Atsushi FunatsuKyoto-Katsura Hospital, 17-banchi, Yamada Hirao-cho, Nishikyo-ku, Kyoto-shi, Kyoto, Zip 6158256, Japan.
Tadahisa OkadaKyoto-Katsura Hospital, 17-banchi, Yamada Hirao-cho, Nishikyo-ku, Kyoto-shi, Kyoto, Zip 6158256, Japan.
Maria MautiPhilips Healthcare, Best, The Netherlands.
Yuki WaizumiPhilips Electronics Japan, Tokyo, Japan.
Shinichi YamadaPhilips Electronics Japan, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Coronary angiography and intervention can expose patients to high radiation dose. This retrospective study quantifies the patient dose reduction due to the introduction of a novel X-ray imaging noise reduction technology using advanced real-time image noise reduction algorithms and optimized acquisition chain for fluoroscopy and exposure in interventional cardiology. Patient, procedure and radiation dose data were retrospectively collected in the period August 2012-August 2013 for 883 patients treated with the image noise reduction technology (referred as "new system"). The same data were collected for 1083 patients in the period April 2011-July 2012 with a system using state-of-the-art image processing and reference acquisition chain (referred as "reference system"). Procedures were divided into diagnostic (CAG) and intervention (PCI). Acquisition parameters such as fluoroscopy time, volume of contrast medium, number of exposure images and number of stored fluoroscopy images were collected to classify procedure complexity. The procedural dose reduction was investigated separately for three main cardiologists. The new system provides significant dose reduction compared to the reference system. Median DAP values decreased for all procedures (p < 0.0001) from 172.7 to 59.4 Gy cm(2), for CAG from 155.1 to 52.0 Gy cm(2) and for PCI from 229.0 to 85.8 Gy cm(2) with reduction quantified at 66, 66 and 63 %, respectively. Based on median values, the dose reduction for all procedures was 68, 60 and 67 % for cardiologists 1, 2 and 3, respectively. The X-ray imaging technology combining advanced real-time image noise reduction algorithms and anatomy-specific optimized fluoroscopy and cine acquisition chain provides 66 % patient dose reduction in interventional cardiology.

Indexed as

AlgorithmsRadiation DosageAgedAged, 80 and overCardiac CatheterizationCineangiographyContrast MediaCoronary AngiographyCoronary Artery DiseaseCoronary VesselsFemaleFluoroscopyHumansMaleMiddle AgedPredictive Value of TestsContrast MediaDAPImage processingInterventional cardiologyRadiation doseX-ray imaging technology

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.