Evidence map›Paper›PMID 25837601›Full record

ArticleNeuroImage2015

Simultaneous multi-slice Turbo-FLASH imaging with CAIPIRINHA for whole brain distortion-free pseudo-continuous arterial spin labeling at 3 and 7 T.

Yi Wang, Steen Moeller, Xiufeng Li, An T Vu, Kate Krasileva, Kamil Ugurbil, Essa Yacoub, Danny J J Wang

Abstract read
In one paragraph

Article in NeuroImage, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

34 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Controlling TMagnetic resonance in medicine · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yi WangLaboratory of FMRI Technology (LOFT), Department of Neurology, University of California Los Angeles, Los Angeles, CA 90095, USA.
Steen MoellerCenter of Magnetic Resonance Research, University of Minnesota, Minneapolis, MN 55455, USA.
Xiufeng LiCenter of Magnetic Resonance Research, University of Minnesota, Minneapolis, MN 55455, USA.
An T VuCenter of Magnetic Resonance Research, University of Minnesota, Minneapolis, MN 55455, USA.
Kate KrasilevaLaboratory of FMRI Technology (LOFT), Department of Neurology, University of California Los Angeles, Los Angeles, CA 90095, USA.
Kamil UgurbilCenter of Magnetic Resonance Research, University of Minnesota, Minneapolis, MN 55455, USA.
Essa YacoubCenter of Magnetic Resonance Research, University of Minnesota, Minneapolis, MN 55455, USA.
Danny J J WangLaboratory of FMRI Technology (LOFT), Department of Neurology, University of California Los Angeles, Los Angeles, CA 90095, USA. Electronic address: jwang71@gmail.com.

Funding

Mapping the Human Connectome: Structure, Function, and HeritabilityU54MH091657 · NIMH · WASHINGTON UNIVERSITY · PI UGURBIL, KAMIL, VAN ESSEN, DAVID C · 2010 to 2014
$34.7M
ZOOMED FUNCT IMAGING IN HUMAN BRAIN AT 7T W/ SIMULT HIGH SPATIAL &TEMPORAL RESP41RR008079 · NCRR · UNIVERSITY OF MINNESOTA TWIN CITIES · PI VAN DE MOORTELE, PIERRE-FRANCOIS · 1993 to 2011
$16.3M
Visual TestingP30EY011374 · NEI · UNIVERSITY OF MINNESOTA TWIN CITIES · PI NEWMAN, ERIC A · 1996 to 2019
$8.8M
NMR Imaging and SpectroscopyP41EB015894 · NIBIB · UNIVERSITY OF MINNESOTA · PI UGURBIL, KAMIL · 2012 to 2017
$8.4M
Pediatric Template of Brain PerfusionR01MH080892 · NIMH · UNIVERSITY OF PENNSYLVANIA · PI WANG, DANNY JJ · 2009 to 2013
$3.3M
Non-contrast 4-D Dynamic MRA in Arteriovenous Malformation (AVM)R01EB014922 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI WANG, DANNY JJ · 2013 to 2016
$1.8M
Arterial Spin Labeled Perfusion MRI in Acute Ischemic StrokeR01NS081077 · NINDS · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI WANG, DANNY JJ · 2012 to 2014
$1.3M
NCRR NIH HHS P41 RR008079NCRR NIH HHS P41 RR08079NEI NIH HHS P30 EY011374NIBIB NIH HHS P41 EB015894NIBIB NIH HHS R01 EB014922NIBIB NIH HHS R01-EB014922NIMH NIH HHS R01 MH080892NIMH NIH HHS R01-MH080892NIMH NIH HHS U54 MH091657NIMH NIH HHS U54MH091657NINDS NIH HHS R01 NS081077NINDS NIH HHS R01-NS081077
6 · The paper itself

Abstract

Simultaneous multi-slice (SMS) or multiband (MB) imaging has recently been attempted for arterial spin labeled (ASL) perfusion MRI in conjunction with echo-planar imaging (EPI) readout. It was found that SMS-EPI can reduce the T1 relaxation effect of the label and improve image coverage and resolution with little penalty in signal-to-noise ratio (SNR). However, EPI still suffers from geometric distortion and signal dropout from field inhomogeneity effects especially at high and ultrahigh magnetic fields. Here we present a novel scheme for achieving high fidelity distortion-free quantitative perfusion imaging by combining pseudo-continuous ASL (pCASL) with SMS Turbo-FLASH (TFL) readout at both 3 and 7 T. Bloch equation simulation was performed to characterize and optimize the TFL-based pCASL perfusion signal. Two MB factors (3 and 5) were implemented in SMS-TFL pCASL and compared with standard 2D TFL and EPI pCASL sequences. The temporal SNR of SMS-TFL pCASL relative to that of standard TFL pCASL was 0.76 ± 0.10 and 0.74 ± 0.11 at 7 T and 0.70 ± 0.05 and 0.65 ± 0.05 at 3T for MB factor of 3 and 5, respectively. By implementing background suppression in conjunction with SMS-TFL at 3T, the relative temporal SNR improved to 0.84 ± 0.09 and 0.79 ± 0.10 for MB factor of 3 and 5, respectively. Compared to EPI pCASL, significantly increased temporal SNR (p<0.001) and improved visualization of orbitofrontal cortex were achieved using SMS-TFL pCASL. By combining SMS acceleration with TFL pCASL, we demonstrated the feasibility for whole brain distortion-free quantitative mapping of cerebral blood flow at high and ultrahigh magnetic fields.

Indexed as

Spin LabelsAdultAlgorithmsBrainCerebral ArteriesCerebrovascular CirculationComputer SimulationEcho-Planar ImagingElectromagnetic FieldsFemaleHumansImage Processing, Computer-AssistedMalePerfusion ImagingSignal-To-Noise RatioYoung AdultSpin LabelsArterial spin labeling (ASL)Cerebral blood flow (CBF)Multiband (MB)Simultaneous multi-slice (SMS)Turbo-FLASH (TFL)

Identifiers

PMID25837601
PMCPMC4433786

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.