ArticleOptics express2015
Temperature sensor based on a hybrid ITO-silica resonant cavity.
Article in Optics express, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- A high-resolution strain-gauge nanolaser.Nature communications · 2016Article
- Label-free, single molecule resonant cavity detection: a double-blind experimental study.Sensors (Basel, Switzerland) · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Integrated optical devices comprised of multiple material systems are able to achieve unique performance characteristics, enabling applications in sensing and in telecommunications. Due to ease of fabrication, the majority of previous work has focused on polymer-dielectric or polymer-semiconductor systems. However, the environmental stability of polymers is limited. In the present work, a hybrid device comprised of an indium tin oxide (ITO) coating on a silicon dioxide toroidal resonant cavity is fabricated. Finite element method simulations of the optical field in the multi-material device are performed, and the optical mode profile is significantly altered by the high index film. The quality factor is also measured and is material loss limited. Additionally, its performance as a temperature sensor is characterized. Due to the high thermo-optic coefficient of ITO and the localization of the optical field in the ITO layer, the hybrid temperature sensor demonstrates a nearly 3-fold improvement in performance over the conventional silica device.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.