Evidence map›Paper›PMID 25829942›Full record

ArticleJournal of occupational medicine and toxicology (London, England)2015

Multi-capillary column-ion mobility spectrometry (MCC-IMS) as a new method for the quantification of occupational exposure to sevoflurane in anaesthesia workplaces: an observational feasibility study.

Nils Kunze, Cathrin Weigel, Wolfgang Vautz, Katrin Schwerdtfeger, Melanie Jünger, Michael Quintel, Thorsten Perl

Open access · goldAbstract read
In one paragraph

Article in Journal of occupational medicine and toxicology (London, England), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 21 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Nils KunzeDepartment for Anaesthesiology, Centre for Anaesthesiology, Emergency and Intensive Care Medicine, University Medical Centre, University of Göttingen, Robert-Koch-Straße 40, 37075 Göttingen, Germany.
Cathrin WeigelDepartment for Anaesthesiology, Centre for Anaesthesiology, Emergency and Intensive Care Medicine, University Medical Centre, University of Göttingen, Robert-Koch-Straße 40, 37075 Göttingen, Germany.
Wolfgang VautzLeibniz-Insitut für Analytische Wissenschaften - ISAS - e. V, Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany.
Katrin SchwerdtfegerDepartment for Anaesthesiology, Centre for Anaesthesiology, Emergency and Intensive Care Medicine, University Medical Centre, University of Göttingen, Robert-Koch-Straße 40, 37075 Göttingen, Germany.
Melanie JüngerDepartment of Molecular Plant Genetics, University of Hamburg, Ohnhorststraße 18, 22609 Hamburg, Germany.
Michael QuintelDepartment for Anaesthesiology, Centre for Anaesthesiology, Emergency and Intensive Care Medicine, University Medical Centre, University of Göttingen, Robert-Koch-Straße 40, 37075 Göttingen, Germany.
Thorsten PerlDepartment for Anaesthesiology, Centre for Anaesthesiology, Emergency and Intensive Care Medicine, University Medical Centre, University of Göttingen, Robert-Koch-Straße 40, 37075 Göttingen, Germany.
University of Göttingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOccupational exposure to sevoflurane has the potential to cause health damage in hospital personnel. Workplace contamination with the substance mostly is assessed by using photoacoustic infrared spectrometry with detection limits of 10 ppbv. Multi-capillary column-ion mobility spectrometry (MCC-IMS) could be an alternative technology for the quantification of sevoflurane in the room air and could be even more accurate because of potentially lower detection limits. The aim of this study was to test the hypothesis that MCC-IMS is able to detect and monitor very low concentrations of sevoflurane (<10 ppbv) and to evaluate the exposure of hospital personnel to sevoflurane during paediatric anaesthesia and in the post anaesthesia care unit (PACU).

methodsA MCC-IMS device was calibrated to several concentrations of sevoflurane and limits of detection (LOD) and quantification (LOQ) were calculated. Sevoflurane exposure of hospital personnel was measured at two anaesthesia workplaces and time-weighted average (TWA) values were calculated.

resultsThe LOD was 0.0068 ppbv and the LOQ was 0.0189 ppbv. During paediatric anaesthesia the mean sevoflurane concentration was 46.9 ppbv (8.0 - 314.7 ppbv) with TWA values between 5.8 and 45.7 ppbv. In the PACU the mean sevoflurane concentration was 27.9 ppbv (8.0 - 170.2 ppbv) and TWA values reached from 8.3 to 45.1 ppbv.

conclusionsMCC-IMS shows a significantly lower LOD and LOQ than comparable methods. It is a reliable technology for monitoring sevoflurane concentrations at anaesthesia workplaces and has a particular strength in quantifying low-level contaminations of sevoflurane. The exposure of the personnel working in these areas did not exceed recommended limits and therefore adverse health effects are unlikely.

Indexed as

Ion mobility spectrometryLimit of detectionOccupational exposureRoom air analysesSevofluraneVolatile anaesthetics

Identifiers

PMID25829942
PMCPMC4379543
OpenAlexW2116949784

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.