Evidence map›Paper›PMID 25825618›Full record

ArticleBiomicrofluidics2015

Streamline based design guideline for deterministic microfluidic hydrodynamic single cell traps.

Allan Guan, Aditi Shenoy, Richard Smith, Zhenyu Li

Abstract read
In one paragraph

Article in Biomicrofluidics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Allan GuanDepartment of Biomedical Engineering, The George Washington University , Washington, District of Columbia 20052, USA.ORCID 0000-0001-9292-4582
Aditi ShenoyDepartment of Biomedical Engineering, The George Washington University , Washington, District of Columbia 20052, USA.
Richard SmithDepartment of Biomedical Engineering, The George Washington University , Washington, District of Columbia 20052, USA.
Zhenyu LiDepartment of Biomedical Engineering, The George Washington University , Washington, District of Columbia 20052, USA.ORCID 0000-0002-7752-6225

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A prerequisite for single cell study is the capture and isolation of individual cells. In microfluidic devices, cell capture is often achieved by means of trapping. While many microfluidic trapping techniques exist, hydrodynamic methods are particularly attractive due to their simplicity and scalability. However, current design guidelines for single cell hydrodynamic traps predominantly rely on flow resistance manipulation or qualitative streamline analysis without considering the target particle size. This lack of quantitative design criteria from first principles often leads to non-optimal probabilistic trapping. In this work, we describe an analytical design guideline for deterministic single cell hydrodynamic trapping through the optimization of streamline distributions under laminar flow with cell size as a key parameter. Using this guideline, we demonstrate an example design which can achieve 100% capture efficiency for a given particle size. Finite element modelling was used to determine the design parameters necessary for optimal trapping. The simulation results were subsequently confirmed with on-chip microbead and white blood cell trapping experiments.

Identifiers

PMID25825618
PMCPMC4352164

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.