Evidence map›Paper›PMID 25823381›Full record

ArticlePractical radiation oncology

Utility and validation of biomechanical deformable image registration in low-contrast images.

Michael Velec, Titania Juang, Joanne L Moseley, Mark Oldham, Kristy K Brock

Abstract read
In one paragraph

Article in Practical radiation oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Implementing Radiation Dose-Volume Liver Response in Biomechanical Deformable Image Registration.International journal of radiation oncology, biology, physics · 2017
    Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Michael VelecRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada. Electronic address: michael.velec@rmp.uhn.ca.
Titania JuangDepartment of Radiation Oncology Physics, Duke University Medical Center, Durham, North Carolina.
Joanne L MoseleyRadiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario, Canada.
Mark OldhamDepartment of Radiation Oncology Physics, Duke University Medical Center, Durham, North Carolina.
Kristy K BrockDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan.

Funding

Dynamic multi-organ anatomical models for hypofractionated RT design and deliveryR01CA124714 · NCI · UNIVERSITY HEALTH NETWORK · PI BROCK, KRISTY · 2008 to 2011
$797k
Canadian Institutes of Health ResearchNCI NIH HHS 5R01CA124714-02NCI NIH HHS R01 CA124714
6 · The paper itself

Abstract

purposeThe application of a biomechanical deformable image registration algorithm has been demonstrated to overcome the potential limitations in the use of intensity-based algorithms on low-contrast images that lack prominent features. Because validation of deformable registration is particularly challenging on such images, the dose distribution predicted via a biomechanical algorithm was evaluated using the measured dose from a deformable dosimeter. METHODS AND MATERIALS: A biomechanical model-based image registration algorithm registered computed tomographic (CT) images of an elastic radiochromic dosimeter between its undeformed and deformed positions. The algorithm aligns the external boundaries of the dosimeter, created from CT contours, and the internal displacements are solved by modeling the physical material properties of the dosimeter. The dosimeter was planned and irradiated in its deformed position, and subsequently, the delivered dose was measured with optical CT in the undeformed position. The predicted dose distribution, created by applying the deformable registration displacement map to the planned distribution, was then compared with the measured optical CT distribution.

resultsCompared with the optical CT distribution, biomechanical image registration predicted the position and size of the deformed dose fields with mean errors of ≤1 mm (maximum, 3 mm). The accuracy did not differ between cross sections with a greater or lesser deformation magnitude despite the homogenous CT intensities throughout the dosimeter. The overall 3-dimensional voxel passing rate of the predicted distribution was γ3%/3mm = 91% compared with optical CT.

conclusionsBiomechanical registration accurately predicted the deformed dose distribution measured in a deformable dosimeter, whereas previously, evaluations of a commercial intensity-based algorithm demonstrated substantial errors. The addition of biomechanical algorithms to the collection of adaptive radiation therapy tools would be valuable for dose accumulation, particularly in feature-poor images such as cone beam CT and organs such as the liver.

Indexed as

AlgorithmsImage Processing, Computer-AssistedModels, TheoreticalPhantoms, ImagingRadiotherapy Planning, Computer-AssistedTomography, X-Ray Computed

Identifiers

PMID25823381
PMCPMC4494886

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.