Evidence map›Paper›PMID 25814092›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2015

Paraoxonase-1 enzyme activity assay for clinical samples: validation and correlation studies.

Mahdi Garelnabi, Abdelmoneim Younis

Open access · hybridAbstract readValidation Study
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Extracellular production of Ulp1Applied microbiology and biotechnology · 2022
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Mahdi GarelnabiDepartment of Clinical Laboratory and Nutritional Sciences, University of Massachusetts, Lowell, MA, USA.
Abdelmoneim YounisDepartment of Obstetrics and Gynecology, Mercer University School of Medicine & Central Georgia Fertility Institute, Macon, GA, USA.
Mercer University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundParaoxonase-1 (PON1) enzyme is reported in various types of tissues and linked to numerous pathophysiological disorders. It is a potential biomarker in many pathological conditions such as cardiovascular diseases. MATERIAL AND

methodsWe conducted several small-scale studies to evaluate PON1 performance as affected by sample types, storage, and interferences. We also carried out short-term studies to compare the performance of the widely used PON1 assay to the similar commercially available PON1 kit assay method; sample size for the method comparison was N=40, and the number varied for other validation experiments.

resultsOur studies using various types of anticoagulants show that samples collected in tubes with NaF, citrate, EDTA, clot activator, and sodium heparin have increased PON1 levels that are 49%, 24.5%, 19.8%, 11.4%, and 8%, respectively, higher compared to serum samples collected in plain tubes. However, samples collected in lithium heparin tubes demonstrated 10.4% lower PON1 levels compared to serum collected in plain tubes. Biological interference such as hemolysis has little effect on PON1 levels; however, samples spiked with lipids have shown 13% lower PON 1 levels. Our studies comparing the PON1 method commonly available for PON1 assay and a similar non-ELISA commercially available PON1 kit method showed a weak Spearman correlation coefficient of R2=0.40 for the range of 104.9-245.6 U/L.

conclusionsThe current study provides new validation data on enzyme PON1 performance. While no appreciable change was seen with storage, samples type affects the enzyme performance. Our results should encourage additional clinical studies to investigate other aspects of factors known to affect PON1 enzyme function and performance.

Indexed as

AdultAnticoagulantsAryldialkylphosphataseEnzyme AssaysEnzyme-Linked Immunosorbent AssayFemaleHemolysisHumansReproducibility of ResultsStatistics, NonparametricAnticoagulantsAryldialkylphosphatasePON1 protein, human

Identifiers

PMID25814092
PMCPMC4381856
OpenAlexW2007262179

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.