Evidence map›Paper›PMID 25808775›Full record

ArticleSensors (Basel, Switzerland)2015

Development of a microfluidic-based optical sensing device for label-free detection of circulating tumor cells (CTCs) through their lactic acid metabolism.

Tzu-Keng Chiu, Kin-Fong Lei, Chia-Hsun Hsieh, Hung-Bo Hsiao, Hung-Ming Wang, Min-Hsien Wu

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 38 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Droplets microfluidics platform-A tool for single cell research.Frontiers in bioengineering and biotechnology · 2023
    Review
  5. Article
  6. Microfluidics for the Isolation and Detection of Circulating Tumor Cells.Advances in experimental medicine and biology · 2022
    Article
  7. Review
  8. Review
  9. Review
  10. Article
  11. Observational
  12. Review
  13. Phenotype of circulating tumor cell: face-off between epithelial and mesenchymal masks.Tumour biology : the journal of the International Society for Oncodevelopmental Biology and Medicine · 2016
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Tzu-Keng ChiuDepartment of Chemical and Materials Engineering, Chang Gung University, Taoyuan 33302, Taiwan. b74225@hotmail.com.
Kin-Fong LeiGraduate Institute of Medical Mechatronics, Chang Gung University, Taoyuan 33302, Taiwan. kflei@mail.cgu.edu.tw.
Chia-Hsun HsiehDepartment of Chemical and Materials Engineering, Chang Gung University, Taoyuan 33302, Taiwan. wisdom5000@gmail.com.
Hung-Bo HsiaoGraduate Institute of Biochemical and Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan. harber0815@gmail.com.
Hung-Ming WangDivision of Hematology-Oncology, Department of Internal Medicine, Chang Gung Memorial Hospital, Chang Gung University, Taoyuan 33302, Taiwan. whm526@gmail.com.
Min-Hsien WuGraduate Institute of Biochemical and Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan. mhwu@mail.cgu.edu.tw.
Chang Gung University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study reports a microfluidic-based optical sensing device for label-free detection of circulating tumor cells (CTCs), a rare cell species in blood circulation. Based on the metabolic features of cancer cells, live CTCs can be quantified indirectly through their lactic acid production. Compared with the conventional schemes for CTC detection, this label-free approach could prevent the biological bias due to the heterogeneity of the surface antigens on cancer cells. In this study, a microfluidic device was proposed to generate uniform water-in-oil cell-encapsulating micro-droplets, followed by the fluorescence-based optical detection of lactic acid produced within the micro-droplets. To test its feasibility to quantify cancer cells, experiments were carried out. Results showed that the detection signals were proportional to the number of cancer cells within the micro-droplets, whereas such signals were insensitive to the existence and number of leukocytes within. To further demonstrate its feasibility for cancer cell detection, the cancer cells with known cell number in a cell suspension was detected based on the method. Results revealed that there was no significant difference between the detected number and the real number of cancer cells. As a whole, the proposed method opens up a new route to detect live CTCs in a label-free manner.

Indexed as

Biosensing TechniquesMicrofluidic Analytical TechniquesCell Line, TumorCell SeparationCell SurvivalHumansLactic AcidLeukocytesNeoplasmsNeoplastic Cells, CirculatingOptical DevicesLactic Acid

Identifiers

PMID25808775
PMCPMC4435186
OpenAlexW2054012937

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.