Evidence map›Paper›PMID 25801979›Full record

ArticleJournal of applied microbiology2015

Calibration of optimal use parameters for an ultraviolet light-emitting diode in eliminating bacterial contamination on needleless connectors.

M P Hutchens, S L Drennan, E D Cambronne

Open access · greenAbstract readEvaluation Study
In one paragraph

Article in Journal of applied microbiology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

M P HutchensDepartment of Anesthesiology & Perioperative Medicine, Oregon Health & Science University, Portland, OR, USA.
S L DrennanDepartment of Molecular Microbiology & Immunology, Oregon Health & Science University, Portland, OR, USA.
E D CambronneDepartment of Molecular Microbiology & Immunology, Oregon Health & Science University, Portland, OR, USA.
Oregon Health & Science University · US

Funding

Oregon Clinical and Translational Research InstituteUL1TR000128 · NCATS · OREGON HEALTH & SCIENCE UNIVERSITY · PI ELLISON, DAVID H · 2012 to 2015
$28.7M
Sex Difference in Renal Injury After Cardiac Arrest:Mechanisms of Estrogen ActionK08DK090754 · NIDDK · OREGON HEALTH & SCIENCE UNIVERSITY · PI HUTCHENS, MICHAEL P · 2011 to 2015
$757k
NCATS NIH HHS UL1 TR000128NIDDK NIH HHS DK090754NIDDK NIH HHS K08 DK090754
6 · The paper itself

Abstract

aimsNeedleless connectors may develop bacterial contamination and cause central-line-associated bloodstream infections (CLABSI) despite rigorous application of best-practice. Ultraviolet (UV) light-emitting diodes (LED) are an emerging, increasingly affordable disinfection technology. We tested the hypothesis that a low-power UV LED could reliably eliminate bacteria on needleless central-line ports in a laboratory model of central-line contamination. METHODS AND

resultsNeedleless central-line connectors were inoculated with Staphylococcus aureus. A 285 nm UV LED was used in calibrated fashion to expose contaminated connectors. Ports were directly applied to agar plates and flushed with sterile saline, allowing assessment of bacterial survival on the port surface and in simulated usage flow-through fluid. UV applied to needleless central-line connectors was highly lethal at 0·5 cm distance at all tested exposure times. At distances >1·5 cm both simulated flow-through and port surface cultures demonstrated significant bacterial growth following UV exposure. Logarithmic-phase S. aureus subcultures were highly susceptible to UV induction/maintenance dosing.

conclusionsLow-power UV LED doses at fixed time and distance from needleless central-line connector ports reduced cultivable S. aureus from >10(6) CFU to below detectable levels in this laboratory simulation of central-line port contamination. SIGNIFICANCE AND IMPACT OF THE STUDY: Low-power UV LEDs may represent a feasible alternative to current best-practice in connector decontamination.

Indexed as

BacteriaCalibrationDisinfectionEquipment and Supplies, HospitalEquipment ContaminationNeedlesUltraviolet Rayscentral-line-associated bloodstream infectionscentral venous catheterdisinfectionneedleless connectorultraviolet light-emitting diode

Identifiers

PMID25801979
PMCPMC4586062
OpenAlexW2007133835

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.