ArticleDer Orthopade2015
[Patella in Place Balancer: Technique for total knee arthroplasty].
Article in Der Orthopade, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Using a patella reduced technique while balancing a TKA results in restored physiological strain in the collateral ligaments: an ex vivo kinematic analysis.Archives of orthopaedic and trauma surgery · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe gap-balancing technique is well established in primary total knee arthroplasty to determine femoral rotation and flexion gap stability. However, it has been reported that the everted or luxated extensor mechanism during this procedure in addition to soft tissue releases performed may cause inaccurate flexion-gap determination and thus result in malpositioning of the femur or instability. In this article the alternative technique of a Patella in Place Balancer (PIPB) with a no tissue release philosophy is introduced.
methodIn this procedure, at first, the tibia resection is performed and a tibia baseplate inserted. Then, two pins are drilled into the sagittal profile of the femoral condyles. After anatomical repositioning of the extensor apparatus the pins are screwed in until the flexion gap is spanned. In this position femoral component orientation is determined parallel to the tibia. We describe the current clinical experience based on a retrospective review of 3,000 patients. Moreover, initial results of a prospective study are outlined.
resultsThe PIPB technique was suitable for the treatment of primary and secondary gonarthrosis if the collateral ligaments were intact. The detected revision rate was about 1.21 %. Only 2 % of the treated patients reported back with an unsatisfactory outcome 1 year after surgery. In the prospective survey of 33 patients a significant improvement in the KOOS Score could be documented (29.3 points preoperatively vs. 63.5 postoperatively (p < 0.05)). DISCUSSION: The PIPB overcomes the major limitation of the gap balancing technique with regard to the inaccuracy caused by the dislocated extensor mechanism. After a learning curve, the technique appears to be safe and reliable. Preliminary data show promising results.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.