Evidence map›Paper›PMID 25798613›Full record

Trial reportPloS one2015

Limitations of stroke volume estimation by non-invasive blood pressure monitoring in hypergravity.

Olivier Manen, Caroline Dussault, Fabien Sauvet, Stéphanie Montmerle-Borgdorff

Registry-linked trialOpen access · goldAbstract readClinical Trial
In one paragraph

Trial report in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04369976 (Estimating the Optimal G Level for Training and Rehabilitation on a Short Arm Human Centrifuge), which is not on this map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04369976 naactive not recruitingnot on this mapstarted 2020, after this paper: background citation

Estimating the Optimal G Level for Training and Rehabilitation on a Short Arm Human Centrifuge

TypeinterventionalSponsorGreek Aerospace Medical Association and Space ResearchRan2020 to 2025Enrolled105ConditionsMultiple Sclerosis, Stroke, Pulmonary Disease, Chronic Obstructive, AgedArmsARTIFICIAL GRAVITY COMBINED WITH EXERCISE
3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. A Cardiac Force Index Applied to the G Tolerance Test and Surveillance among Male Military Aircrew.International journal of environmental research and public health · 2021
    Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Olivier ManenPercy Military Hospital, Aeromedical Centre, Clamart, France.
Caroline DussaultArmed Forces Biomedical Research Institute (IRBA), Brétigny-sur-Orge, France.
Fabien SauvetArmed Forces Biomedical Research Institute (IRBA), Brétigny-sur-Orge, France; EA7330 VIFASOM, Paris Descartes University, Hotel Dieu, Paris, France.
Stéphanie Montmerle-BorgdorffArmed Forces Biomedical Research Institute (IRBA), Brétigny-sur-Orge, France.
Hôpital d'instruction des Armées Percy · FRUniversité Paris Cité · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAltitude and gravity changes during aeromedical evacuations induce exacerbated cardiovascular responses in unstable patients. Non-invasive cardiac output monitoring is difficult to perform in this environment with limited access to the patient. We evaluated the feasibility and accuracy of stroke volume estimation by finger photoplethysmography (SVp) in hypergravity.

methodsFinger arterial blood pressure (ABP) waveforms were recorded continuously in ten healthy subjects before, during and after exposure to +Gz accelerations in a human centrifuge. The protocol consisted of a 2-min and 8-min exposure up to +4 Gz. SVp was computed from ABP using Liljestrand, systolic area, and Windkessel algorithms, and compared with reference values measured by echocardiography (SVe) before and after the centrifuge runs.

resultsThe ABP signal could be used in 83.3% of cases. After calibration with echocardiography, SVp changes did not differ from SVe and values were linearly correlated (p<0.001). The three algorithms gave comparable SVp. Reproducibility between SVp and SVe was the best with the systolic area algorithm (limits of agreement -20.5 and +38.3 ml).

conclusionsNon-invasive ABP photoplethysmographic monitoring is an interesting technique to estimate relative stroke volume changes in moderate and sustained hypergravity. This method may aid physicians for aeronautic patient monitoring.

Indexed as

HypergravityAdultAlgorithmsBlood PressureBlood Pressure DeterminationFingersHumansMalePhotoplethysmographyReproducibility of ResultsSignal Processing, Computer-AssistedStroke VolumeSystoleTime Factors

Identifiers

PMID25798613
PMCPMC4370450
OpenAlexW2329001170

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.