Evidence map›Paper›PMID 25798314›Full record

ArticleBiomedical optics express2015

3D multifocus astigmatism and compressed sensing (3D MACS) based superresolution reconstruction.

Jiaqing Huang, Mingzhai Sun, Kristyn Gumpper, Yuejie Chi, Jianjie Ma

Abstract read
In one paragraph

Article in Biomedical optics express, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jiaqing HuangDepartment of Surgery, Davis Heart and Lung Research Institute, The Ohio State University, Columbus, OH, 43210, USA ; Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, 43210, USA ; These authors contribute equally to this work.
Mingzhai SunDepartment of Surgery, Davis Heart and Lung Research Institute, The Ohio State University, Columbus, OH, 43210, USA ; These authors contribute equally to this work.
Kristyn GumpperDepartment of Surgery, Davis Heart and Lung Research Institute, The Ohio State University, Columbus, OH, 43210, USA.
Yuejie ChiDepartment of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, 43210, USA ; Department of Biomedical Informatics, The Ohio State University, Columbus, OH, 43210, USA.
Jianjie MaDepartment of Surgery, Davis Heart and Lung Research Institute, The Ohio State University, Columbus, OH, 43210, USA ; jianjie.ma@osumc.edu.

Funding

Modulation of MG53 Function in Cardiac Membrane RepairR01HL069000 · NHLBI · UNIV OF MED/DENT NJ-R W JOHNSON MED SCH · PI MA, JIANJIE · 2002 to 2016
$5.3M
Ca Sparks in Muscle Aging and DystrophyR01AG028614 · NIA · UNIV OF MED/DENT NJ-R W JOHNSON MED SCH · PI MA, JIANJIE · 2006 to 2016
$4.1M
MG53-Mediated Membrane Repair in Muscle Physiology and DiseaseR01AR061385 · NIAMS · UNIV OF MED/DENT NJ-R W JOHNSON MED SCH · PI LIN, PEI-HUI · 2011 to 2020
$3.8M
6 · The paper itself

Abstract

Single molecule based superresolution techniques (STORM/PALM) achieve nanometer spatial resolution by integrating the temporal information of the switching dynamics of fluorophores (emitters). When emitter density is low for each frame, they are located to the nanometer resolution. However, when the emitter density rises, causing significant overlapping, it becomes increasingly difficult to accurately locate individual emitters. This is particularly apparent in three dimensional (3D) localization because of the large effective volume of the 3D point spread function (PSF). The inability to precisely locate the emitters at a high density causes poor temporal resolution of localization-based superresolution technique and significantly limits its application in 3D live cell imaging. To address this problem, we developed a 3D high-density superresolution imaging platform that allows us to precisely locate the positions of emitters, even when they are significantly overlapped in three dimensional space. Our platform involves a multi-focus system in combination with astigmatic optics and an ℓ 1-Homotopy optimization procedure. To reduce the intrinsic bias introduced by the discrete formulation of compressed sensing, we introduced a debiasing step followed by a 3D weighted centroid procedure, which not only increases the localization accuracy, but also increases the computation speed of image reconstruction. We implemented our algorithms on a graphic processing unit (GPU), which speeds up processing 10 times compared with central processing unit (CPU) implementation. We tested our method with both simulated data and experimental data of fluorescently labeled microtubules and were able to reconstruct a 3D microtubule image with 1000 frames (512×512) acquired within 20 seconds.

Indexed as

(100.0100) Image processing(100.6640) Superresolution(110.4155) Multiframe image processing(180.0180) Microscopy(180.6900) Three-dimensional microscopy

Identifiers

PMID25798314
PMCPMC4361444

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.