Trial reportClinical orthopaedics and related research2016
The John Insall Award: No Functional Benefit After Unicompartmental Knee Arthroplasty Performed With Patient-specific Instrumentation: A Randomized Trial.
Trial report in Clinical orthopaedics and related research, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
32 citing papers in PubMed, 75 citations in OpenAlex.
- The impact of patient-specific instrumentation on unicompartmental knee arthroplasty: a prospective randomised controlled study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018Trial
- Three dimensional printing in unicompartmental knee arthroplasty: current evidence and future directions.International orthopaedics · 2026Review
- No advantage for patient-specific UKA in comparison with standard UKA regarding clinical and functional results at short-term follow-up.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Observational
- Patient-specific versus off-the-shelf unicompartmental knee arthroplasty during level walking.Journal of experimental orthopaedics · 2025Article
- Does patient-specific instrument or robot improve imaging and functional outcomes in unicompartmental knee arthroplasty? A bayesian analysis.Archives of orthopaedic and trauma surgery · 2024Article
- Article
- Robotic Versus Conventional Unicompartmental Knee Surgery: A Comprehensive Systematic Review and Meta-Analysis.Cureus · 2023Review
- Patient Specific Instruments and Patient Individual Implants-A Narrative Review.Journal of personalized medicine · 2023Review
- The Use of Computerized Tomography Scans in Elective Knee and Hip Arthroplasty-What Do They Tell Us and at What Risk?Arthroplasty today · 2022Article
- Advances in the Application of Three-dimensional Printing for the Clinical Treatment of Osteoarticular Defects.Current medical science · 2022Review
- [Focal femoral resurfacing and unicompartmental knee replacement : Between osteotomy and total knee replacement].Der Orthopade · 2021Review
- Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study.Archives of orthopaedic and trauma surgery · 2021Article
- [New technologies (robotics, "custom-made") for unicondylar knee arthroplasty-contra].Der Orthopade · 2021Review
- Unicompartmental knee arthroplasty, an enigma, and the ten enigmas of medial UKA.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2020Review
- Curve location influences spinal balance in coronal and sagittal planes but not transversal trunk motion in adolescents with idiopathic scoliosis: a prospective observational study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2020Observational
- Patient-specific instrumentation does not improve tibial component coronal alignment for medial UKA compared to conventional instrumentation.Journal of experimental orthopaedics · 2020Article
- Characterization of trunk motion in adolescents with right thoracic idiopathic scoliosis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2019Article
- Do patient-specific instruments (PSI) for UKA allow non-expert surgeons to achieve the same saw cut accuracy as expert surgeons?Archives of orthopaedic and trauma surgery · 2018Article
- A high rate of tibial plateau fractures after early experience with patient-specific instrumentation for unicompartmental knee arthroplasties.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018Article
- Unicompartmental knee arthroplasty: Current indications, technical issues and results.EFORT open reviews · 2018Article
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundComponent alignment can influence implant longevity as well as perhaps pain and function after unicompartmental knee arthroplasty (UKA), but correct alignment is not consistently achieved. To increase the likelihood that good alignment will be achieved during surgery, smart tools such as robotics or patient-specific instrumentation (PSI) have been introduced. QUESTIONS/PURPOSES: We hypothesized that UKA performed with PSI would result in improved level gait as ascertained with three-dimensional analysis, implant positioning, and patient-reported outcomes measured by a validated scoring system when compared with conventional instrumentation 3 months and 1 year after surgery.
methodsWe randomized 60 patients into two groups using either the PSI technique or a conventional technique. All patients were operated on using the same technique and the same cemented metal-backed implant. Mean age of the patients was 63 ± 4 years (range, 54-72 years) and mean body mass index was 28 ± 3 kg/m(2). Patients were evaluated preoperatively, at 3 months, and 1 year after surgery by an independent observer blind to the type of technique. Gait parameters were assessed with three-dimensional analysis during level walking preoperatively and at 1 year, frontal and sagittal position of the implant was evaluated on full-length radiographs at 3 months, and subjective functional outcome and quality of life using routine questionnaires (SF-12, new Knee Society Score [KSS], Knee Injury and Osteoarthritis Outcome Score) at 3 months and 1 year. This study had 80% power to detect a 15% difference in walking speed at the p < 0.05 level.
resultsOne year after surgery, there were no differences between the two groups in the analyzed gait spatiotemporal parameters, respectively, for PSI UKA and conventional UKA : double limb support 31% (25%-54%) versus 30% (23%-56%; p = 0.67) and walking speed (1.59 m/s [0.86-1.87 m/s] versus 1.57 m/s [0.71-1.96 m/s]; p = 0.41). No difference was observed between the two groups in terms of lower limb alignment (PSI group 178° ± 3°, conventional group 178° ± 4°; p = 0.24) or implant positioning on mediolateral and anteroposterior radiographs. There were no differences in the functional score between the PSI and conventional TKA groups at 3 months and 1 year after surgery: KSS objective knee scores (PSI: 85 ± 8 points at 3 months, 87 ± 5 points at 1 year and conventional instrumentation: 82 ± 8 points at 3 months 83 ± 6 points at 1 year; p = 0.10) and functional activity scores were similar in both group (PSI: 71 ± 12 points at 3 months and 74 ± 7 points at 1 year versus conventional group: 73 ± 11 points at 3 months and 75 ± 6 at 1 year; p = 0.9).
conclusionsOur observations suggest that PSI may confer small, if any, advantage in alignment, pain, or function after UKA. This argument can therefore not be used to justify the extra cost and uncertainty related to this technique. LEVEL OF EVIDENCE: Level I, therapeutic study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.