Evidence map›Paper›PMID 25790620›Full record

ArticleThe Journal of heart valve disease2014

Effect of mitral annuloplasty device shape and size on leaflet and myofiber stress following repair of posterior leaflet prolapse: a patient-specific finite element simulation.

William G Morrel, Liang Ge, Zhihong Zhang, Eugene A Grossi, Julius M Guccione, Mark B Ratcliffe

Abstract read
In one paragraph

Article in The Journal of heart valve disease, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Surgical as Opposed to Transcatheter Aortic Valve Replacement Improves Basal Interventricular Septal Hypertrophy.Circulation journal : official journal of the Japanese Circulation Society · 2018
    Trial
  2. Mitral Valve Prolapse: A Disease of Valve and Ventricle.Journal of the American College of Cardiology · 2018
    Article
  3. Finite Element Modeling of Mitral Valve Repair.Journal of biomechanical engineering · 2016
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

William G Morrel
Liang Ge
Zhihong Zhang
Eugene A Grossi
Julius M Guccione
Mark B Ratcliffe

Funding

VISUALIZATION TOOLS FOR AUTOMATED MOLECULAR MICROSCOPYP41RR008605 · NCRR · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI MCCAMMON, JAMES ANDREW · 1994 to 2011
$28.1M
QUANTITATIVE ANALYSIS OF LEFT VENTRICULPLASTY--CHFR01HL063348 · NHLBI · NORTHERN CALIFORNIA INSTITUTE RES &EDUC · PI RATCLIFFE, MARK B · 2000 to 2017
$6.8M
VIRTUAL TOOLS FOR CARDIAC VENTRICULAR REMODELING SURGERYR01HL077921 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI GUCCIONE, JULIUS MATTEO · 2006 to 2015
$3.4M
Surgery for Ischemic Mitral RegurgitationR01HL084431 · NHLBI · NORTHERN CALIFORNIA INSTITUTE/RES/EDU · PI RATCLIFFE, MARK B · 2008 to 2011
$2.5M
NCRR NIH HHS P41 RR008605NHLBI NIH HHS R01 HL063348NHLBI NIH HHS R01 HL077921NHLBI NIH HHS R01 HL084431NHLBI NIH HHS R01-HL-63348
6 · The paper itself

Abstract

background and aim of the studyMitral annuloplasty (MA) devices are available in different shapes and sizes, but the preferred shape and size are unclear.

methodsA previously described and validated finite element (FE) model of the left ventricle (LV) with mitral valve (MV) based on magnetic resonance imaging and three-dimensional echocardiography images from a patient with posterior leaflet (PL; P2) prolapse was used in this study. FE models of MA devices with different shapes (flat partial, shallow saddle, pronounced saddle) and sizes (36-30) were created. Virtual leaflet resection + MA with each shape and size were simulated. Leaflet geometry, stresses in the leaflets and base of the LV, and forces in the chordae and MA sutures were calculated.

resultsAll MA shapes increased the mitral coaptation length, reduced the elevated PL stress at end-diastole (ED) and end-systole (ES) that occurred after leaflet resection, and reduced anterior leaflet (AL) stress at ES. MA devices of all shapes and sizes modestly reduced myofiber stress at the LV base in ED and ES. In general, saddle-shaped devices had the greatest effect.

conclusionAll MA shapes increased coaptation length and reduced mitral leaflet stress and myofiber stress in the base of the LV. an additional reduction in MA size further increased coaptation length and reduced leaflet and myofiber stress. In general, saddle-shaped devices had the greatest effect.

Indexed as

Mitral Valve ProlapseBiomechanical PhenomenaFinite Element AnalysisHeart VentriclesHumansImaging, Three-DimensionalMitral ValveMitral Valve AnnuloplastyModels, CardiovascularPatient-Specific ModelingPostoperative ComplicationsProsthesis DesignProsthesis FailureStress, Mechanical

Identifiers

PMID25790620
PMCPMC6040586
OpenAlexW79342690

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.