Evidence map›Paper›PMID 25790032›Full record

ArticleNanoscale2015

New surface radiolabeling schemes of super paramagnetic iron oxide nanoparticles (SPIONs) for biodistribution studies.

Prakash D Nallathamby, Ninell P Mortensen, Heather A Palko, Mike Malfatti, Catherine Smith, James Sonnett, Mitchel J Doktycz, Baohua Gu, Ryan K Roeder, Wei Wang and 1 more

Abstract read
In one paragraph

Article in Nanoscale, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Biocompatible, Multi-Mode, Fluorescent,Pharmaceuticals (Basel, Switzerland) · 2022
    Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Prakash D NallathambyBattelle Center for Fundamental and Applied Systems Toxicology, Battelle Memorial Institute, Columbus, OH 43201, USA.
Ninell P Mortensen
Heather A Palko
Mike Malfatti
Catherine Smith
James Sonnett
Mitchel J Doktycz
Baohua Gu
Ryan K Roeder
Wei Wang
Scott T Retterer

Funding

Resource for the Development of Biomedical Accelerator Mass Spectrometry (AMS)P41GM103483 · NIGMS · UNIVERSITY OF CALIF-LAWRNC LVRMR NAT LAB · PI TURTELTAUB, KENNETH W. · 2012 to 2019
$12.0M
Mentoring in Drug Abuse NeuroimagingK05DA031247 · NIDA · UNIVERSITY OF UTAH · PI RENSHAW, PERRY FRANKLIN · 2011 to 2015
$661k
NIGMS NIH HHS P41 GM103483
6 · The paper itself

Abstract

Nanomaterial based drug delivery systems allow for the independent tuning of the surface chemical and physical properties that affect their biodistribution in vivo and the therapeutic payloads that they are intended to deliver. Additionally, the added therapeutic and diagnostic value of their inherent material properties often provides extra functionality. Iron based nanomaterials with their magnetic properties and easily tailorable surface chemistry are of particular interest as model systems. In this study the core radius of the iron oxide nanoparticles (NPs) was 14.08 ± 3.92 nm while the hydrodynamic radius of the NPs, as determined by Dynamic Light Scattering (DLS), was between 90-110 nm. In this study, different approaches were explored to create radiolabeled NPs that are stable in solution. The NPs were functionalized with polycarboxylate or polyamine surface functional groups. Polycarboxylate functionalized NPs had a zeta potential of -35 mV and polyamine functionalized NPs had a zeta potential of +40 mV. The polycarboxylate functionalized NPs were chosen for in vivo biodistribution studies and hence were radiolabeled with (14)C, with a final activity of 0.097 nCi mg(-1) of NPs. In chronic studies, the biodistribution profile is tracked using low level radiolabeled proxies of the nanoparticles of interest. Conventionally, these radiolabeled proxies are chemically similar but not chemically identical to the non-radiolabeled NPs of interest. This study is novel as different approaches were explored to create radiolabeled NPs that are stable, possess a hydrodynamic radius of <100 nm and most importantly they exhibit an identical surface chemical functionality as their non-radiolabeled counterparts. Identical chemical functionality of the radiolabeled probes to the non-radiolabeled probes was an important consideration to generate statistically similar biodistribution data sets using multiple imaging and detection techniques. The radiolabeling approach described here is applicable to the synthesis of a large class of nanomaterials with multiple core and surface functionalities. This work combined with the biodistribution data suggests that the radiolabeling schemes carried out in this study have broad implications for use in pharmacokinetic studies for a variety of nanomaterials.

Indexed as

Drug Delivery SystemsAnimalsCarbonCarboxylic AcidsCell LineFourier AnalysisHydrodynamicsIronLightMaleMetal NanoparticlesMiceMice, Inbred BALB CMicroscopy, Electron, ScanningNanotechnologyOxidesCarbonCarboxylic AcidsIronOxidesPolyaminesSilicon

Identifiers

PMID25790032
PMCPMC4847546

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.