Evidence map›Paper›PMID 25784964›Full record

ArticleBiomicrofluidics2015

Three dimensional passivated-electrode insulator-based dielectrophoresis.

Diana Nakidde, Phillip Zellner, Mohammad Mehdi Alemi, Tyler Shake, Yahya Hosseini, Maria V Riquelme, Amy Pruden, Masoud Agah

Abstract read
In one paragraph

Article in Biomicrofluidics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Study on non-bioparticles andRSC advances · 2020
    Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Diana NakiddeVT MEMS - Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24060 , USA.
Phillip ZellnerVT MEMS - Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24060 , USA.
Mohammad Mehdi AlemiORCID 0000-0002-4257-3566
Tyler ShakeVT MEMS - Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24060 , USA.
Yahya HosseiniVT MEMS - Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24060 , USA.ORCID 0000-0002-7866-235X
Maria V RiquelmePruden Lab - Department of Civil and Environmental Engineering , Virginia Tech, Blacksburg, Virginia 24060, USA.
Amy PrudenPruden Lab - Department of Civil and Environmental Engineering , Virginia Tech, Blacksburg, Virginia 24060, USA.
Masoud AgahVT MEMS - Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, Virginia 24060 , USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, a 3D passivated-electrode, insulator-based dielectrophoresis microchip (3D πDEP) is presented. This technology combines the benefits of electrode-based DEP, insulator-based DEP, and three dimensional insulating features with the goal of improving trapping efficiency of biological species at low applied signals and fostering wide frequency range operation of the microfluidic device. The 3D πDEP chips were fabricated by making 3D structures in silicon using reactive ion etching. The reusable electrodes are deposited on second glass substrate and then aligned to the microfluidic channel to capacitively couple the electric signal through a 100 μm glass slide. The 3D insulating structures generate high electric field gradients, which ultimately increases the DEP force. To demonstrate the capabilities of 3D πDEP, Staphylococcus aureus was trapped from water samples under varied electrical environments. Trapping efficiencies of 100% were obtained at flow rates as high as 350 μl/h and 70% at flow rates as high as 750 μl/h. Additionally, for live bacteria samples, 100% trapping was demonstrated over a wide frequency range from 50 to 400 kHz with an amplitude applied signal of 200 Vpp. 20% trapping of bacteria was observed at applied voltages as low as 50 Vpp. We demonstrate selective trapping of live and dead bacteria at frequencies ranging from 30 to 60 kHz at 400 Vpp with over 90% of the live bacteria trapped while most of the dead bacteria escape.

Identifiers

PMID25784964
PMCPMC4344466

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.