ArticleBiomedizinische Technik. Biomedical engineering2015
Segmented independent component analysis for improved separation of fetal cardiac signals from nonstationary fetal magnetocardiograms.
Article in Biomedizinische Technik. Biomedical engineering, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Fetal magnetocardiograms (fMCGs) have been successfully processed with independent component analysis (ICA) to separate the fetal cardiac signals, but ICA effectiveness can be limited by signal nonstationarities due to fetal movements. We propose an ICA-based method to improve the quality of fetal signals separated from fMCG affected by fetal movements. This technique (SegICA) includes a procedure to detect signal nonstationarities, according to which the fMCG recordings are divided in stationary segments that are then processed with ICA. The first and second statistical moments and the signal polarity reversal were used at different threshold levels to detect signal transients. SegICA effectiveness was assessed in two fMCG datasets (with and without fetal movements) by comparing the signal-to-noise ratio (SNR) of the signals extracted with ICA and with SegICA. Results showed that the SNR of fetal signals affected by fetal movements improved with SegICA, whereas the SNR gain was negligible elsewhere. The best measure to detect signal nonstationarities of physiological origin was signal polarity reversal at threshold level 0.9. The first statistical moment also provided good results at threshold level 0.6. SegICA seems a promising method to separate fetal cardiac signals of improved quality from nonstationary fMCG recordings affected by fetal movements.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.