Evidence map›Paper›PMID 25774329›Full record

ArticleTranslational vision science & technology2015

Fixation Stability Measurement Using Two Types of Microperimetry Devices.

Hongting Liu, Millena G Bittencourt, Raafay Sophie, Yasir J Sepah, Mostafa Hanout, Zubir Rentiya, Rachel Annam, Hendrik P N Scholl, Quan Dong Nguyen

Open access · bronzeAbstract read
In one paragraph

Article in Translational vision science & technology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Reply.Turkish journal of ophthalmology · 2026
    Article
  3. Preferred Retinal Locus in Juvenile Macular Dystrophy.Turkish journal of ophthalmology · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Detecting Diabetic Retinal Neuropathy Using Fundus Perimetry.International journal of molecular sciences · 2021
    Review
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Hongting LiuWilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA ; Visual Science and Optometry Center, People's Hospital of Guangxi Zhuang Autonomous Region, Nanning, Guangxi Province, China.
Millena G BittencourtWilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA.
Raafay SophieWilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA.
Yasir J SepahTruhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska, USA.
Mostafa HanoutTruhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska, USA.
Zubir RentiyaWilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA.
Rachel AnnamWilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA.
Hendrik P N SchollWilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA.
Quan Dong NguyenTruhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska, USA.
Johns Hopkins University · USUniversity of Nebraska Medical Center · USThe People's Hospital of Guangxi Zhuang Autonomous Region · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe compared the fixation stability measurements obtained with two microperimeters, the Micro Perimeter 1 (MP-1) and the Spectral OCT/SLO (OCT/SLO), in subjects with and without maculopathies.

methodsA total of 41 eyes with no known ocular diseases and 45 eyes with maculopathies were enrolled in the study. Both eyes of each participant had a 20-second fixation test using the MP-1 and OCT/SLO. The bivariate contour ellipse area (BCEA) was used for fixation stability evaluation.

resultsIn the normal group, BCEA was 2.93 ± 0.32 log minarc

conclusionFixation stability assessment yields similar results using the OCT/SLO and MP-1. A major difference in sampling rate between the two microperimeters does not significantly affect BCEA measurements. TRANSLATIONAL RELEVANCE: Fixation stability assessments are comparable and interchangeable between the OCT/SLO and the MP-1.

Indexed as

comparisonfixation stabilitymicroperimetry

Identifiers

PMID25774329
PMCPMC4356036
OpenAlexW2109490266

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.