Ion trap with narrow aperture detection electrodes for Fourier transform ion cyclotron resonance mass spectrometry.

Konstantin O Nagornov, Anton N Kozhinov, Oleg Y Tsybin, Yury O Tsybin

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.Journal of the American Society for Mass Spectrometry · 2017
    Article
  8. Parallel Spectral Acquisition with Orthogonal ICR Cells.Journal of the American Society for Mass Spectrometry · 2017
    Article
  9. Article
  10. Developments in FTICR-MS and Its Potential for Body Fluid Signatures.International journal of molecular sciences · 2015
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Konstantin O NagornovBiomolecular Mass Spectrometry Laboratory, Ecole Polytechnique Fédérale de Lausanne, 1015, Lausanne, Switzerland.
Anton N Kozhinov
Oleg Y Tsybin
Yury O Tsybin

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The current paradigm in ion trap (cell) design for Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is the ion detection with wide aperture detection electrodes. Specifically, excitation and detection electrodes are typically 90° wide and positioned radially at a similar distance from the ICR cell axis. Here, we demonstrate that ion detection with narrow aperture detection electrodes (NADEL) positioned radially inward of the cell's axis is feasible and advantageous for FT-ICR MS. We describe design details and performance characteristics of a 10 T FT-ICR MS equipped with a NADEL ICR cell having a pair of narrow aperture (flat) detection electrodes and a pair of standard 90° excitation electrodes. Despite a smaller surface area of the detection electrodes, the sensitivity of the NADEL ICR cell is not reduced attributable to improved excite field distribution, reduced capacitance of the detection electrodes, and their closer positioning to the orbits of excited ions. The performance characteristics of the NADEL ICR cell are comparable with the state-of-the-art FT-ICR MS implementations for small molecule, peptide, protein, and petroleomics analyses. In addition, the NADEL ICR cell's design improves the flexibility of ICR cells and facilitates implementation of advanced capabilities (e.g., quadrupolar ion detection for improved mainstream applications). It also creates an intriguing opportunity for addressing the major bottleneck in FTMS-increasing its throughput via simultaneous acquisition of multiple transients or via generation of periodic non-sinusoidal transient signals.