ArticleJournal of the American Society for Mass Spectrometry2015
Ion trap with narrow aperture detection electrodes for Fourier transform ion cyclotron resonance mass spectrometry.
Article in Journal of the American Society for Mass Spectrometry, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Histone Analysis Using Mobility- and Mass-Selected Ultraviolet Photodissociation in Tandem with Ultra-High-Resolution Mass Spectrometry.Analytical chemistry · 2025Article
- Applications and advancements of FT-ICR-MS for interactome studies.Mass spectrometry reviews · 2022Review
- Application of frequency multiple FT-ICR-MS signal acquisition for improved proteome research.International journal of mass spectrometry · 2021Article
- Parallel detection in a single ICR cell: Spectral averaging and improved S/N without increased acquisition time.International journal of mass spectrometry · 2018Article
- Cyclotron Phase-Coherent Ion Spatial Dispersion in a Non-Quadratic Trapping Potential is Responsible for FT-ICR MS at the Cyclotron Frequency.Journal of the American Society for Mass Spectrometry · 2018Article
- Multiparticle Simulations of Quadrupolar Ion Detection in an Ion Cyclotron Resonance Cell with Four Narrow Aperture Detection Electrodes.Journal of the American Society for Mass Spectrometry · 2018Article
- Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.Journal of the American Society for Mass Spectrometry · 2017Article
- Parallel Spectral Acquisition with Orthogonal ICR Cells.Journal of the American Society for Mass Spectrometry · 2017Article
- Oversampling Selective Accumulation Trapped Ion Mobility Spectrometry Coupled to FT-ICR MS: Fundamentals and Applications.Analytical chemistry · 2016Article
- Developments in FTICR-MS and Its Potential for Body Fluid Signatures.International journal of molecular sciences · 2015Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The current paradigm in ion trap (cell) design for Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is the ion detection with wide aperture detection electrodes. Specifically, excitation and detection electrodes are typically 90° wide and positioned radially at a similar distance from the ICR cell axis. Here, we demonstrate that ion detection with narrow aperture detection electrodes (NADEL) positioned radially inward of the cell's axis is feasible and advantageous for FT-ICR MS. We describe design details and performance characteristics of a 10 T FT-ICR MS equipped with a NADEL ICR cell having a pair of narrow aperture (flat) detection electrodes and a pair of standard 90° excitation electrodes. Despite a smaller surface area of the detection electrodes, the sensitivity of the NADEL ICR cell is not reduced attributable to improved excite field distribution, reduced capacitance of the detection electrodes, and their closer positioning to the orbits of excited ions. The performance characteristics of the NADEL ICR cell are comparable with the state-of-the-art FT-ICR MS implementations for small molecule, peptide, protein, and petroleomics analyses. In addition, the NADEL ICR cell's design improves the flexibility of ICR cells and facilitates implementation of advanced capabilities (e.g., quadrupolar ion detection for improved mainstream applications). It also creates an intriguing opportunity for addressing the major bottleneck in FTMS-increasing its throughput via simultaneous acquisition of multiple transients or via generation of periodic non-sinusoidal transient signals.