SynthesisThe Cochrane database of systematic reviews2015
Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas.
Synthesis in The Cochrane database of systematic reviews, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 74 papers, 10 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
74 citing papers in PubMed, 10 syntheses or guidelines pooled it, 125 citations in OpenAlex.
- Diagnostic accuracy of rapid and point-of-care tests forFrontiers in parasitology · 2026Pooled it
- A Mini-Review on Elisa-Based Diagnosis of Schistosomiasis.Current molecular medicine · 2024Pooled it
- A systematic and meta-analysis review on the diagnostic accuracy of antibodies in the serological diagnosis of COVID-19.Systematic reviews · 2021Pooled it
- Evaluation, Validation, and Recognition of the Point-of-Care Circulating Cathodic Antigen, Urine-Based Assay for MappingThe American journal of tropical medicine and hygiene · 2020Pooled it
- An update on non-invasive urine diagnostics for human-infecting parasitic helminths: what more could be done and how?Parasitology · 2020Pooled it
- [Recommendations for the screening for infectious diseases, mental health, and female genital mutilation in immigrant patients seen in Primary Care].Atencion primaria · 2020Guideline
- The epidemiology and chemotherapeutic approaches to the control of urinary schistosomiasis in school-age children (SAC): a systematic review.BMC infectious diseases · 2019Pooled it
- Effectiveness of Screening and Treatment Approaches for Schistosomiasis and Strongyloidiasis in Newly-Arrived Migrants from Endemic Countries in the EU/EEA: A Systematic Review.International journal of environmental research and public health · 2018Pooled it
- Accuracy of point-of-care testing for circulatory cathodic antigen in the detection of schistosome infection: systematic review and meta-analysis.Bulletin of the World Health Organization · 2016Pooled it
- Considering treatment of male genital schistosomiasis as a tool for future HIV prevention: a systematic review.International journal of public health · 2015Pooled it
- Determinants of Urogenital Schistosomiasis Among Pregnant Women and its Association With Pregnancy Outcomes, Neonatal Deaths, and Child Growth.The Journal of infectious diseases · 2021Trial
- Trial
- Refining Diagnosis ofFrontiers in immunology · 2018Trial
- Ultrasonographic evaluation of urinary tract morbidity in school-aged and preschool-aged children infected with Schistosoma haematobium and its evolution after praziquantel treatment: A randomized controlled trial.PLoS neglected tropical diseases · 2017Trial
- Factors affecting detection and quantification of Schistosoma haematobium eggs in pooled urine samples.PLoS neglected tropical diseases · 2026Article
- Diagnostic Performance and Discordance of Kato-Katz Method, POC-CCA Test, and PCR in DetectingDiseases (Basel, Switzerland) · 2026Article
- Crystal structure of Schistosoma mansoni cathepsin D1 in complex with a nanobody reveals the conformation of the propeptide-bound state.Acta crystallographica. Section D, Structural biology · 2026Article
- Prevalence ofEnvironmental health insights · 2026Article
- Performance of Urine Reagent Test Strips in DetectingMicroorganisms · 2025Article
- Evaluation of the recombinant proteinParasitology · 2025Article
14 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 6 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPoint-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use.
objectivesTo summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. SEARCH
methodsWe searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. SELECTION CRITERIA: We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). MAIN
resultsWe included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopyCompared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21).When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assayCompared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). AUTHORS'
conclusionsAmong the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy.The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.