Evidence map›Paper›PMID 25734405›Full record

ArticleJournal of biomedical optics2015

Second derivative multispectral algorithm for quantitative assessment of cutaneous tissue oxygenation.

Jiwei Huang, Shiwu Zhang, Surya Gnyawali, Chandan K Sen, Ronald X Xu

Open access · bronzeAbstract read
In one paragraph

Article in Journal of biomedical optics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Jiwei HuangThe Ohio State University, Department of Biomedical Engineering, Columbus, Ohio 43210, United States.
Shiwu ZhangUniversity of Science and Technology of China, Department of Precision Machinery and Precision Instrumentation, Hefei, Anhui 230027, China.
Surya GnyawaliThe Ohio State University, Department of Surgery, Columbus, Ohio 43210, United States.
Chandan K SenThe Ohio State University, Department of Surgery, Columbus, Ohio 43210, United States.
Ronald X XuThe Ohio State University, Department of Biomedical Engineering, Columbus, Ohio 43210, United StatesbUniversity of Science and Technology of China, Department of Precision Machinery and Precision Instrumentation, Hefei, Anhui 230027, China.
The Ohio State University · USUniversity of Science and Technology of China · CN

Funding

Redox Control of Wound HealingR01GM069589 · NIGMS · OHIO STATE UNIVERSITY · PI SEN, CHANDAN K · 2004 to 2013
$2.3M
Tissue Oxygenation and Wound HealingR01GM077185 · NIGMS · OHIO STATE UNIVERSITY · PI SEN, CHANDAN K · 2007 to 2016
$2.3M
Oxygen Sensitive Signaling in Primary Cardiac FibroblastR01HL073087 · NHLBI · OHIO STATE UNIVERSITY · PI SEN, CHANDAN K · 2004 to 2007
$1.3M
NHLBI NIH HHS HL073087NHLBI NIH HHS R01 HL073087NIGMS NIH HHS GM 069589NIGMS NIH HHS GM 077185NIGMS NIH HHS R01 GM069589NIGMS NIH HHS R01 GM077185
6 · The paper itself

Abstract

We report a second derivative multispectral algorithm for quantitative assessment of cutaneous tissue oxygen saturation (StO₂). The algorithm is based on a forward model of light transport in multilayered skin tissue and an inverse algorithm for StO₂ reconstruction. Based on the forward simulation results, a parameter of a second derivative ratio (SDR) is derived as a function of cutaneous tissue StO₂. The SDR function is optimized at a wavelength set of 544, 552, 568, 576, 592, and 600 nm so that cutaneous tissue StO₂ can be derived with minimal artifacts by blood concentration, tissue scattering, and melanin concentration. The proposed multispectral StO₂ imaging algorithm is verified in both benchtop and in vivo experiments. The experimental results show that the proposed multispectral imaging algorithm is able to map cutaneous tissue StO₂ in high temporal resolution with reduced measurement artifacts induced by different skin conditions in comparison with other three commercial tissue oxygen measurement systems. These results indicate that the multispectral StO₂ imaging technique has the potential for noninvasive and quantitative assessment of skin tissue oxygenation with a high temporal resolution.

Indexed as

AlgorithmsOxygen ConsumptionAnalysis of VarianceHumansMelaninsOxygenSkinSkin PigmentationMelaninsOxygen

Identifiers

PMID25734405
PMCPMC4347514
OpenAlexW2132515665

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.