Evidence map›Paper›PMID 25715753›Full record

ArticleMedical & biological engineering & computing2015

Effects of endothelium, stent design and deployment on the nitric oxide transport in stented artery: a potential role in stent restenosis and thrombosis.

Xiao Liu, Min Wang, Nan Zhang, Zhanming Fan, Yubo Fan, Xiaoyan Deng

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. [Review of studies on the biomechanical modelling of the coupling effect between stent degradation and blood vessel remodeling].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2020
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Xiao LiuKey Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100191, China.
Min Wang
Nan Zhang
Zhanming Fan
Yubo Fan
Xiaoyan Deng
Beihang University · CNCapital University · USPLA 306 Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Extrinsic factors such as stent design, deployment and damage to endothelium are associated with stent restenosis and thrombosis. We hypothesize that these extrinsic factors can affect nitric oxide (NO) concentration and disturb its distribution in the stented artery, hence contributing to stent restenosis and thrombosis. We numerically investigated the effects of different endothelium coverage and high-risk factors including thicker strut, stent malapposition and overlapping on the NO distribution in the stented artery. The decrease in the endothelium coverage would greatly reduce the NO concentration, and the location of the coverage relative to the strut significantly affected its distribution. Strut protrusion and thicker strut would induce flow disruption, which not only decreases NO concentration but also greatly changes NO distribution, leading to very low NO concentration near the strut, especially the distal region. Likewise, strut malapposition and overlap would both diminish the NO concentration. However, the distribution of NO for relatively large malapposition was much evener than that for small malapposition. Moreover, proper deployment of the overlapping strut would result in relatively high and uniform NO concentration. In conclusion, less endothelium coverage, thicker struts and improper stent deployment may decrease NO concentration and lead to relatively low NO concentration near the strut.

Indexed as

StentsComputer SimulationCoronary Artery DiseaseCoronary VesselsEndothelium, VascularHemodynamicsHumansModels, CardiovascularNitric OxideProsthesis DesignThrombosisNitric Oxide

Identifiers

PMID25715753
OpenAlexW2033524557

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.