ArticleAnnals of the American Thoracic Society2015
Reliability of a Noninvasive Measure of V./Q. Mismatch for Bronchopulmonary Dysplasia.
Article in Annals of the American Thoracic Society, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 19 citations in OpenAlex.
- Use of ventilation/perfusion mismatch to guide individualised CPAP level selection in preterm infants: a feasibility trial.Archives of disease in childhood. Fetal and neonatal edition · 2023Trial
- Hazards to avoid in future neonatal studies of nasal high-frequency oscillatory ventilation: lessons from an early terminated trial.BMC research notes · 2019Trial
- Functional morphometry: non-invasive estimation of the alveolar surface area in extremely preterm infants.Pediatric research · 2023Article
- Unstable SpOFrontiers in physiology · 2023Article
- Clinical Characteristics and Outcomes Until 2 Years of Age in Preterm Infants With Typical Chest Imaging Findings of Bronchopulmonary Dysplasia: A Propensity Score Analysis.Frontiers in pediatrics · 2021Article
- Using the fetal oxyhaemoglobin dissociation curve to calculate the ventilation/perfusion ratio and right to left shunt in healthy newborn infants.Journal of clinical monitoring and computing · 2019Article
- Ventilation/perfusion ratio and right to left shunt in healthy newborn infants.Journal of clinical monitoring and computing · 2017Article
- Bronchopulmonary dysplasia: A review of pathogenesis and pathophysiology.Respiratory medicine · 2017Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 6 institutions in 3 countries.
Funding
Abstract
rationaleCurrently used definitions of bronchopulmonary dysplasia (BPD) lack a continuous measure of disease severity.
objectivesTo determine if an indirect measure of V./Q. mismatch is reliable when simplified to facilitate more widespread use for grading disease severity in BPD at 36 weeks postmenstrual age.
methodsWe used prospectively collected data from 32 preterm infants undergoing an oxygen reduction test at 36 weeks postmenstrual age to perform a simplified indirect assessment of V./Q. mismatch for each infant. Independent raters applied the model, and interrater reliability for a quantitative measure of mismatch was measured by intraclass correlation coefficient. A receiver operating characteristic curve evaluated the impact of increasing degrees of V./Q. mismatch on diagnosing BPD as defined by oxygen reduction test failure. MEASUREMENTS AND MAIN
resultsConcordance for the quantitative measure of V./Q. mismatch between independent raters improved from 0.72 (confidence interval [CI], 0.48-0.86) to 0.93 (CI, 0.87-0.96) after refinement of instructions for applying the simplified model. Higher degrees of mismatch were increasingly predictive of oxygen reduction test failure, with a receiver operating characteristic curve analysis area under the curve of 0.83 (CI, 0.68-0.99; P = 0.03).
conclusionsA simplified indirect measure of V./Q. mismatch for diagnosing and grading disease severity in BPD has high reliability and can be performed with data obtained during a standard oxygen reduction test. This should facilitate more widespread investigation of this model as a technique for characterizing BPD severity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.