ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2015
Gated blood pool SPECT: The estimation of right ventricular volume and function is algorithm dependent in a clinical setting.
Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Tales from the future-nuclear cardio-oncology, from prediction to diagnosis and monitoring.European heart journal. Cardiovascular Imaging · 2023Review
- Assessment and diagnosis of right ventricular failure-retrospection and future directions.Frontiers in cardiovascular medicine · 2023Review
- Perioperative right ventricular function and dysfunction in adult cardiac surgery-focused review (part 1-anatomy, pathophysiology, and diagnosis).Indian journal of thoracic and cardiovascular surgery · 2022Review
- Equilibrium radionuclide angiography: Present and future.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Article
- Perspective and future direction of intraventricular mechanical dyssynchrony assessment.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Article
- Heart Rate Expenditure Correlates with Right Ventricular Function.Annals of the American Thoracic Society · 2020Article
- RV function improvement following nitric oxide inhalation demonstrated by gated blood pool SPECT in a patient with primary pulmonary hypertension.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018Article
Corrections and comments
- Commented on by
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundGated blood pool SPECT (GBPS) requires further validation for the assessment of the right ventricle (RV). This study evaluated three algorithms: BP-SPECT, QBS, and TOMPOOL (results are referred using this order). We compared (1) their "quantitative-accuracy": estimation of RV ejection fraction (EF), end-diastolic volume (EDV), and cardiac output (CO); (2) their "qualitative-accuracy": threshold values allowing diagnosing an impairment of the RV function; (3) their reproducibility: inter-observer relative variability (IOV). METHODS AND
resultsForty-eight consecutive patients underwent GBPS. Recommended reference standards were used: cardiac magnetic resonance imaging (CMR) (EDV, EF, n = 48), catheter measurements from thermodilution (TD) (CO, n = 25). (1) "Quantitative-accuracy": r = 0.42, 0.30, 0.42 for RVEF (CMR); r = 0.69, 0.77, 0.53 for RVEDV (CMR); 0.32, 0.36, 0.52 for RCO (TD). (2) "Qualitative-accuracy": optimal thresholds were 54.7%, 38.5%, 45.2% (AUC: 0.83, 0.80, 0.79) for RVEF; 229, 180, 94 mL (AUC: 0.83, 0.81, 0.81) for RVEDV; 4.1, 4.4, 2.6 L·minute(-1) (AUC: 0.73, 0.77, 0.80) for RCO. (3) Reproducibility: IOV was 5% ± 6%, 8% ± 12%, 17% ± 18% for RVEF; 6% ± 8%, 4% ± 4%, 21% ± 18% for RVEDV; 8% ± 8%, 11% ± 15%, 24% ± 20% for RCO.
conclusionDiagnostic accuracies are similar. A CMR-based calibration is required for a quantitative-analysis (cautious interpretation) or an accurate qualitative analysis (thresholds must be adjusted). Automatic procedures (BP-SPECT, QBS) offer the best compromise accuracy/reproducibility.
Indexed as
Identifiers
25698473What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.