ArticleHypertension research : official journal of the Japanese Society of Hypertension2015
Accurate quantitative measurements of brachial artery cross-sectional vascular area and vascular volume elastic modulus using automated oscillometric measurements: comparison with brachial artery ultrasound.
Article in Hypertension research : official journal of the Japanese Society of Hypertension, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Sensitive detection of atherosclerotic coronary artery disease by a novel index of pressure-area relationship of the brachial artery.Heart and vessels · 2025Article
- Volume Elastic Modulus, Vascular Function, and Vascular Structure in Patients with Cardiovascular Risk Factors.Journal of atherosclerosis and thrombosis · 2021Article
- Ultrasound-guided arterial catheterization.Anesthesia and pain medicine · 2021Review
- Noninvasive Measurement of Time-Varying Arterial Wall Elastance Using a Single-Frequency Vibration Approach.Sensors (Basel, Switzerland) · 2020Article
- Impella 2.5 Insertion: Which Artery to Access When Femoral Is not an Option?JACC. Case reports · 2020Article
- Evolution and Development of the Atrial Septum.Anatomical record (Hoboken, N.J. : 2007) · 2019Review
- Volume elastic modulus of the brachial artery and coronary artery stenosis in patients with suspected stable coronary artery disease.Heart and vessels · 2016Article
- Anatomical and Functional Estimations of Brachial Artery Diameter and Elasticity Using Oscillometric Measurements with a Quantitative Approach.Pulse (Basel, Switzerland) · 2016Review
- Enlargement of the brachial artery: significance of measurement.Hypertension research : official journal of the Japanese Society of Hypertension · 2015Article
Corrections and comments
- Commented on by
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Increasing vascular diameter and attenuated vascular elasticity may be reliable markers for atherosclerotic risk assessment. However, previous measurements have been complex, operator-dependent or invasive. Recently, we developed a new automated oscillometric method to measure a brachial artery's estimated area (eA) and volume elastic modulus (V(E)). The aim of this study was to investigate the reliability of new automated oscillometric measurement of eA and V(E). Rest eA and V(E) were measured using the recently developed automated detector with the oscillometric method. eA was estimated using pressure/volume curves and V(E) was defined as follows (V(E)=Δ pressure/ (100 × Δ area/area) mm Hg/%). Sixteen volunteers (age 35.2±13.1 years) underwent the oscillometric measurements and brachial ultrasound at rest and under nitroglycerin (NTG) administration. Oscillometric measurement was performed twice on different days. The rest eA correlated with ultrasound-measured brachial artery area (r=0.77, P<0.001). Rest eA and VE measurement showed good reproducibility (eA: intraclass correlation coefficient (ICC)=0.88, V(E): ICC=0.78). Under NTG stress, eA was significantly increased (12.3±3.0 vs. 17.1±4.6 mm(2), P<0.001), and this was similar to the case with ultrasound evaluation (4.46±0.72 vs. 4.73±0.75 mm, P<0.001). V(E) was also decreased (0.81±0.16 vs. 0.65±0.11 mm Hg/%, P<0.001) after NTG. Cross-sectional vascular area calculated using this automated oscillometric measurement correlated with ultrasound measurement and showed good reproducibility. Therefore, this is a reliable approach and this modality may have practical application to automatically assess muscular artery diameter and elasticity in clinical or epidemiological settings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.