Evidence map›Paper›PMID 25688542›Full record

ArticleJournal of biomedical optics2015

Noninvasive glucose sensing by transcutaneous Raman spectroscopy.

Wei-Chuan Shih, Kate L Bechtel, Mihailo V Rebec

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Review
  3. Noninvasive Glucose Sensing In Vivo.Sensors (Basel, Switzerland) · 2023
    Review
  4. Article
  5. Article
  6. [Research progress on minimally invasive and non-invasive blood glucose detection methods].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2023
    Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Wei-Chuan ShihUniversity of Houston, Department of Electrical and Computer Engineering, 4800 Calhoun Road, Houston, Texas 77204, United StatesbUniversity of Houston, Department of Biomedical Engineering, 4800 Calhoun Road, Houston, Texas 77204, United StatescSpectrosco.
Kate L BechtelSpectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States.
Mihailo V RebeciSense CGM, 27700SW 95th Avenue, Wilsonville, Oregon 97070, United States.

Funding

WIDE-FIELD REFLECTION PHASE MICROSCOPYP41RR002594 · NCRR · MASSACHUSETTS INSTITUTE OF TECHNOLOGY · PI PARK, YOUNGKYU · 1985 to 2011
$12.3M
NCRR NIH HHS P41 RR002594NCRR NIH HHS P41-RR02594
6 · The paper itself

Abstract

We present the development of a transcutaneous Raman spectroscopy system and analysis algorithm for noninvasive glucose sensing. The instrument and algorithm were tested in a preclinical study in which a dog model was used. To achieve a robust glucose test system, the blood levels were clamped for periods of up to 45 min. Glucose clamping and rise/fall patterns have been achieved by injecting glucose and insulin into the ear veins of the dog. Venous blood samples were drawn every 5 min and a plasma glucose concentration was obtained and used to maintain the clamps, to build the calibration model, and to evaluate the performance of the system. We evaluated the utility of the simultaneously acquired Raman spectra to be used to determine the plasma glucose values during the 8-h experiment. We obtained prediction errors in the range of ~1.5-2  mM. These were in-line with a best-case theoretical estimate considering the limitations of the signal-to-noise ratio estimates. As expected, the transition regions of the clamp study produced larger predictive errors than the stable regions. This is related to the divergence of the interstitial fluid (ISF) and plasma glucose values during those periods. Two key contributors to error beside the ISF/plasma difference were photobleaching and detector drift. The study demonstrated the potential of Raman spectroscopy in noninvasive applications and provides areas where the technology can be improved in future studies.

Indexed as

AlgorithmsAnimalsBlood GlucoseCalibrationDogsEquipment DesignInsulinLeast-Squares AnalysisReproducibility of ResultsScattering, RadiationSignal-To-Noise RatioSkinSpectrophotometrySpectrum Analysis, RamanVibrationBlood GlucoseInsulin

Identifiers

PMID25688542
PMCPMC4330710

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.