ArticleExperimental biology and medicine (Maywood, N.J.)2015
Temporal responses of human endothelial and smooth muscle cells exposed to uniaxial cyclic tensile strain.
Article in Experimental biology and medicine (Maywood, N.J.), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 22 citations in OpenAlex.
- Pulsatile low shear stress increases susceptibility to endothelial inflammation via upregulation of IFT and activation of YAP.APL bioengineering · 2025Article
- Effects of high-frequency mechanical stimuli on flow related vascular cell biology.The International journal of artificial organs · 2024Review
- Exosomal miR-423-5p Derived from Cerebrospinal Fluid Pulsation Stress-Stimulated Osteoblasts Improves Angiogenesis of Endothelial Cells via DUSP8/ERK1/2 Signaling Pathway.Stem cells international · 2024Article
- A Statistical Mechanics Approach to Describe Cell Reorientation Under Stretch.Bulletin of mathematical biology · 2023Article
- Organ-on-a-chip technologies for biomedical research and drug development: A focus on the vasculature.Smart medicine · 2023Article
- Design and aligner-assisted fast fabrication of a microfluidic platform for quasi-3D cell studies on an elastic polymer.Bioactive materials · 2022Article
- Role of the vascular endothelial sodium channel activation in the genesis of pathologically increased cardiovascular stiffness.Cardiovascular research · 2022Review
- Integration of substrate- and flow-derived stresses in endothelial cell mechanobiology.Communications biology · 2021Review
- Article
- Endothelial Plasticity: Shifting Phenotypes through Force Feedback.Stem cells international · 2016Review
- Nano- and microstructured materials for in vitro studies of the physiology of vascular cells.Beilstein journal of nanotechnology · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The physiology of vascular cells depends on stimulating mechanical forces caused by pulsatile flow. Thus, mechano-transduction processes and responses of primary human endothelial cells (ECs) and smooth muscle cells (SMCs) have been studied to reveal cell-type specific differences which may contribute to vascular tissue integrity. Here, we investigate the dynamic reorientation response of ECs and SMCs cultured on elastic membranes over a range of stretch frequencies from 0.01 to 1 Hz. ECs and SMCs show different cell shape adaptation responses (reorientation) dependent on the frequency. ECs reveal a specific threshold frequency (0.01 Hz) below which no responses is detectable while the threshold frequency for SMCs could not be determined and is speculated to be above 1 Hz. Interestingly, the reorganization of the actin cytoskeleton and focal adhesions system, as well as changes in the focal adhesion area, can be observed for both cell types and is dependent on the frequency. RhoA and Rac1 activities are increased for ECs but not for SMCs upon application of a uniaxial cyclic tensile strain. Analysis of membrane protrusions revealed that the spatial protrusion activity of ECs and SMCs is independent of the application of a uniaxial cyclic tensile strain of 1 Hz while the total number of protrusions is increased for ECs only. Our study indicates differences in the reorientation response and the reaction times of the two cell types in dependence of the stretching frequency, with matching data for actin cytoskeleton, focal adhesion realignment, RhoA/Rac1 activities, and membrane protrusion activity. These are promising results which may allow cell-type specific activation of vascular cells by frequency-selective mechanical stretching. This specific activation of different vascular cell types might be helpful in improving strategies in regenerative medicine.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials