SynthesisThe Cochrane database of systematic reviews2015
Thromboelastography (TEG) and rotational thromboelastometry (ROTEM) for trauma induced coagulopathy in adult trauma patients with bleeding.
Synthesis in The Cochrane database of systematic reviews, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03380767 (Use of Viscoelastic Tests in the Treatment of Trauma-induced Coagulopathy), which is not on this map. Cited by 91 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Use of Viscoelastic Tests in the Treatment of Trauma-induced Coagulopathy: a Pragmatic Randomized Clinical Trial Comparing Viscoelastic Tests With Conventional Assays.
Who cites it
91 citing papers in PubMed, 5 syntheses or guidelines pooled it.
- Blood transfusion strategies for major bleeding in trauma.The Cochrane database of systematic reviews · 2025Pooled it
- Traumatic Brain Injury Is Associated With Both Hemorrhagic Stroke and Ischemic Stroke: A Systematic Review and Meta-Analysis.Frontiers in neuroscience · 2022Pooled it
- The use of viscoelastic haemostatic assays in non-cardiac surgical settings: a systematic review and meta-analysis.Blood transfusion = Trasfusione del sangue · 2018Pooled it
- Thromboelastography (TEG) or thromboelastometry (ROTEM) to monitor haemostatic treatment versus usual care in adults or children with bleeding.The Cochrane database of systematic reviews · 2016Pooled it
- Thromboelastography (TEG) and rotational thromboelastometry (ROTEM) for trauma induced coagulopathy in adult trauma patients with bleeding.The Cochrane database of systematic reviews · 2015Pooled it
- Viscoelastic haemostatic assay augmented protocols for major trauma haemorrhage (ITACTIC): a randomized, controlled trial.Intensive care medicine · 2021Trial
- Trial
- Outcomes after concomitant traumatic brain injury and hemorrhagic shock: A secondary analysis from the Pragmatic, Randomized Optimal Platelets and Plasma Ratios trial.The journal of trauma and acute care surgery · 2017Trial
- Fibrinogen Early In Severe Trauma studY (FEISTY): study protocol for a randomised controlled trial.Trials · 2017Trial
- Early Rotem Evaluation Abnormalities May Be Associated with Hemorragic but Not Thromboembolic Complications in Patients with Major Trauma Referred to Hospital Within the First Hour.Journal of clinical medicine · 2026Article
- Management of trauma-induced coagulopathy in the perioperative setting: What is the role of anesthesia?Transfusion · 2026Review
- Sonorheometry to detect traumatic induced coagulopathy during initial management of trauma patients: an observational, multi-center study.Scandinavian journal of trauma, resuscitation and emergency medicine · 2026Observational
- Methodological and Pathophysiological Considerations in Obesity-Associated Thrombosis.International journal of molecular sciences · 2026Review
- Platelet and Fibrinogen Contribution to Clot Strength in Premature Neonates with Sepsis.Children (Basel, Switzerland) · 2025Article
- Utility of point of care viscoelastic haemostatic assays for trauma patients in the emergency department.Scandinavian journal of trauma, resuscitation and emergency medicine · 2025Observational
- Viscoelastic Hemostatic Assays are Associated With Mortality and Blood Transfusion in a Multicenter Cohort.Journal of the American College of Emergency Physicians open · 2025Article
- Thromboelastography may assess the effect of anticoagulation reversal in intracranial hemorrhage.Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association · 2025Article
- Targeting Inflammation After Hemorrhagic Shock as a Molecular and Experimental Journey to Improve Outcomes: A Review.Cureus · 2025Review
- Machine learning models predict coagulopathy in traumatic brain injury patients in ER.Frontiers in neurology · 2025Article
- Navigating Hemorrhagic Shock: Biomarkers, Therapies, and Challenges in Clinical Care.Biomedicines · 2024Review
31 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
backgroundTrauma-induced coagulopathy (TIC) is a disorder of the blood clotting process that occurs soon after trauma injury. A diagnosis of TIC on admission is associated with increased mortality rates, increased burdens of transfusion, greater risks of complications and longer stays in critical care. Current diagnostic testing follows local hospital processes and normally involves conventional coagulation tests including prothrombin time ratio/international normalized ratio (PTr/INR), activated partial prothrombin time and full blood count. In some centres, thromboelastography (TEG) and rotational thromboelastometry (ROTEM) are standard tests, but in the UK they are more commonly used in research settings.
objectivesThe objective was to determine the diagnostic accuracy of thromboelastography (TEG) and rotational thromboelastometry (ROTEM) for TIC in adult trauma patients with bleeding, using a reference standard of prothrombin time ratio and/or the international normalized ratio. SEARCH
methodsWe ran the search on 4 March 2013. Searches ran from 1970 to current. We searched The Cochrane Library, MEDLINE (OvidSP), EMBASE Classic and EMBASE, eleven other databases, the web, and clinical trials registers. The Cochrane Injuries Group's specialised register was not searched for this review as it does not contain diagnostic test accuracy studies. We also screened reference lists, conducted forward citation searches and contacted authors. SELECTION CRITERIA: We included all cross-sectional studies investigating the diagnostic test accuracy of TEG and ROTEM in patients with clinically suspected TIC, as well as case-control studies. Participants were adult trauma patients in both military and civilian settings. TIC was defined as a PTr/INR reading of 1.2 or greater, or 1.5 or greater. DATA COLLECTION AND ANALYSIS: We piloted and performed all review stages in duplicate, including quality assessment using the QUADAS-2 tool, adhering to guidance in the Cochrane Handbook for Diagnostic Test Accuracy Reviews. We analysed sensitivity and specificity of included studies narratively as there were insufficient studies to perform a meta-analysis. MAIN
resultsThree studies were included in the final analysis. All three studies used ROTEM as the test of global haemostatic function, and none of the studies used TEG. Tissue factor-activated assay EXTEM clot amplitude (CA) was the focus of the accuracy measurements in blood samples taken near to the point of admission. These CAs were not taken at a uniform time after the start of the coagulopathic trace; the time varied from five minutes, to ten minutes and fifteen minutes. The three included studies were conducted in the UK, France and Afghanistan in both civilian and military trauma settings. In two studies, median Injury Severity Scores were 12, inter-quartile range (IQR) 4 to 24; and 22, IQR 12 to 34; and in one study the median New Injury Severity Score was 34, IQR 17 to 43.There were insufficient included studies examining each of the three ROTEM CAs at 5, 10 and 15 minutes to make meta-analysis and investigation of heterogeneity valid. The results of the included studies are thus reported narratively and illustrated by a forest plot and results plotted on the receiver operating characteristic (ROC) plane.For CA5 the accuracy results were sensitivity 70% (95% CI 47% to 87%) and specificity 86% (95% CI 82% to 90%) for one study, and sensitivity 96% (95% CI 88% to 100%) and specificity 58% (95% CI 44% to 72%) for the other.For CA10 the accuracy results were sensitivity 100% (95% CI 94% to 100%) and specificity 70% (95% CI 56% to 82%).For CA15 the accuracy results were sensitivity 88% (95% CI 69% to 97%) and specificity 100% (95% CI 94% to 100%).No uninterpretable ROTEM study results were mentioned in any of the included studies.Risk of bias and concerns around applicability of findings was low across all studies for the patient and flow and timing domains. However, risk of bias and concerns around applicability of findings for the index test domain was either high or unclear, and the risk of bias for the reference standard domain was high. This raised concerns around the interpretation of the sensitivity and specificity results of the included studies, which may be misleading. AUTHORS'
conclusionsWe found no evidence on the accuracy of TEG and very little evidence on the accuracy of ROTEM. The value of accuracy estimates are considerably undermined by the small number of included studies, and concerns about risk of bias relating to the index test and the reference standard. We are unable to offer advice on the use of global measures of haemostatic function for trauma based on the evidence on test accuracy identified in this systematic review. This evidence strongly suggests that at present these tests should only be used for research. We consider more thoroughly what this research could be in the Discussion section.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.