Evidence map›Paper›PMID 25685248›Full record

ArticleThe open orthopaedics journal2015

Early complications following cemented modular hip hemiarthroplasty.

Niall P T Sullivan, Andrew W Hughes, Ruth L Halliday, Abigail L Ward, Tim J S Chesser

Open access · hybridAbstract read
In one paragraph

Article in The open orthopaedics journal, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Niall P T SullivanDepartment of Trauma and Orthopaedics, Southmead Hospital, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK.
Andrew W HughesDepartment of Trauma and Orthopaedics, Southmead Hospital, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK.
Ruth L HallidayDepartment of Trauma and Orthopaedics, Southmead Hospital, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK.
Abigail L WardDepartment of Trauma and Orthopaedics, Southmead Hospital, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK.
Tim J S ChesserDepartment of Trauma and Orthopaedics, Southmead Hospital, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK.
Southmead Hospital · GBNorth Bristol NHS Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionHemiarthroplasty is the recommended treatment for displaced, intracapsular, femoral neck fractures. This study aimed to evaluate the early complications following insertion of the JRI Furlong cemented hemiarthroplasty, a contemporary, modular, double tapered, polished prosthesis.

methodA series of 459 consecutive patients (May 2006 - June 2009) treated with a JRI hemiarthroplasty with a minimum of one-year (1-4years) follow-up were evaluated. Data collected retrospectively from clinical records and hospital databases included patient demographics, mortality, deep infection, dislocation, periprosthetic fracture, and any requirement for revision or complications related to the prosthesis.

resultsFull data were available for 429 of 459 (93%), partial data for 30 (7%). Average age was 83 years (52-100), 76% were female. One-year mortality was 24%. Intraoperative fractures occurred in 17 patients (3.7%). There were two intraoperative deaths. There were nine early deep wound infections (2%). There were two revisions to total hip replacement (THR), four patients required conversion to THR and one underwent an excision arthroplasty procedure. DISCUSSION: Early surgical outcomes for the JRI hemiarthroplasty prosthesis are equivalent or superior to other major hemiarthroplasty prostheses previously reported however, there was a high intraoperative fracture rate of 3.7%. We recommend using a stem one size smaller than the final broach in fragile, osteoporotic bone. No patients re-presented with aseptic loosening or stem failure.

Indexed as

Cementfracturehemiarthroplastyhipmodularorthogeriatric.

Identifiers

PMID25685248
PMCPMC4323769
OpenAlexW2167614460

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.