Evidence map›Paper›PMID 25681949›Full record

ArticleMedical & biological engineering & computing2015

Hemodialysis vascular access stenosis detection using auditory spectro-temporal features of phonoangiography.

Po-Hsun Sung, Chung-Dann Kan, Wei-Ling Chen, Ling-Sheng Jang, Jhing-Fa Wang

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Effect of stenosis shape on the sound emitted from a constricted blood vessel.Medical & biological engineering & computing · 2020
    Article
  7. Flexible, Skin Coupled Microphone Array for Point of Care Vascular Access Monitoring.IEEE transactions on biomedical circuits and systems · 2019
    Article
  8. Stenosis Characterization and Identification for Dialysis Vascular Access.... IEEE Signal Processing in Medicine and Biology Symposium (SPMB). IEEE Signal Processing in Medicine and Biology Symposium · 2018
    Article
  9. Bruit-enhancing phonoangiogram filter using sub-band autoregressive linear predictive coding.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2018
    Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Po-Hsun SungDepartment of Electrical Engineering, National Cheng Kung University, No. 1, University Road, Tainan City, 701, Taiwan, ROC, phsung@gmail.com.
Chung-Dann Kan
Wei-Ling Chen
Ling-Sheng Jang
Jhing-Fa Wang

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

For end-stage renal disease patients undergoing hemodialysis, thrombosis caused by stenosis hinders the long-term use of vascular access. However, traditional spectral bruit analysis techniques for detecting the severity of vascular access stenosis are not robust. Accordingly, the present study proposes an automated method for mimicking a trained practitioner in performing the auscultation process. In the proposed approach, the bruit obtained using a standard phonoangiographic method is transformed into the time-frequency domain, and two spectro-temporal features, namely the auditory spectrum flux and the auditory spectral centroid, are then extracted. The distributions of the two features are analyzed using a multivariate Gaussian distribution (MGD) model. Finally, the distribution parameters of the MGD model are used to detect the presence (or otherwise) of vascular access stenosis. The validity of the proposed approach is investigated using the phonoangiography signals obtained from 16 hemodialysis patients with straight arteriovenous grafts over the upper arm region. The results show that the MGD covariance matrix coefficient of the auditory spectral centroid feature yields an accuracy of 83.87 % in detecting significant vascular access stenosis. Thus, the proposed method has significant potential for the applications of vascular access stenosis detection.

Indexed as

Diagnostic Techniques, CardiovascularSignal Processing, Computer-AssistedAgedAuscultationConstriction, PathologicFemaleHumansMaleMiddle AgedRenal DialysisSpectrum AnalysisVascular Access Devices

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.