ArticleMagnetic resonance imaging2015

Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer.

Donnie Cameron, David M Higgins, Christian Stehning, Marc Kouwenhoven, Mustapha Bouhrara, Michael P Frenneaux, Dana K Dawson, Thomas W Redpath

Abstract read
In one paragraph

Article in Magnetic resonance imaging, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Free-Breathing Ungated Radial Simultaneous Multi-Slice Cardiac T1 Mapping.Journal of magnetic resonance imaging : JMRI · 2025
    Article
  2. Article
  3. Towards accurate and precise TMagma (New York, N.Y.) · 2018
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Donnie CameronThe University of Aberdeen, Aberdeen, UK. Electronic address: d.cameron.09@aberdeen.ac.uk.
David M HigginsPhilips Healthcare, Guildford, Surrey, UK. Electronic address: david.higgins@philips.com.
Christian StehningPhilips Research, Hamburg, Germany. Electronic address: christian.stehning@philips.com.
Marc KouwenhovenPhilips Healthcare, Best, The Netherlands. Electronic address: marc.kouwenhoven@philips.com.
Mustapha BouhraraNational Institute on Aging, National Institutes of Health, Baltimore, MD, USA. Electronic address: mustapha.bouhrara2@nih.gov.
Michael P FrenneauxThe University of Aberdeen, Aberdeen, UK. Electronic address: m.p.frenneaux@abdn.ac.uk.
Dana K DawsonThe University of Aberdeen, Aberdeen, UK. Electronic address: dana.dawson@abdn.ac.uk.
Thomas W RedpathThe University of Aberdeen, Aberdeen, UK. Electronic address: t.redpath@abdn.ac.uk.

Funding

Intramural NIH HHS Z99 AG999999Medical Research Council G1001340
6 · The paper itself

Abstract

backgroundThe purpose of this work was to evaluate different magnetization preparation and readout sequences for modified Look-Locker inversion recovery (MOLLI) toward improved T1 mapping in the heart. Elements investigated include: catalyzation sequences to prepare the magnetization before readout, alternate k-space trajectories, a spoiled gradient recalled echo readout, and a 5b(3b)3b MOLLI sampling scheme ('b' denoting beats).

methodsConventional 3b(3b)3b(3b)5b MOLLI with a linear k-space trajectory was compared to four variants in simulations, in vitro and in vivo (at 3T). Variants were centric conventional MOLLI, centric-paired conventional MOLLI, linear 5b(3b)3b MOLLI and spoiled gradient recalled echo MOLLI. Each of these was applied with three magnetization catalyzation methods, and T1 measurement accuracy and precision were evaluated in simulations via a Monte Carlo algorithm, in a set of calibrated phantoms, and in ten healthy volunteers. Contrast-to-noise, heart rate dependence and B1+ dependence were also evaluated.

resultsA linear k-space trajectory was superior in vitro to centric and centric-paired trajectories. Of the catalyzation methods, preparation of transverse magnetization only-using a linearly increasing flip angle catalyzation-improved MOLLI T1 measurement accuracy, precision, and map quality versus methods that include catalyzation of the longitudinal magnetization. The 5b(3b)3b MOLLI scheme offered comparable native T1 measurement accuracy and precision to conventional MOLLI, despite its shortened acquisition.

conclusionsMOLLI T1 measurement accuracy, precision, and map quality depend on the method of catalyzation of magnetization prior to image acquisition, as well as on the readout method and MOLLI sampling scheme used.

Indexed as

AlgorithmsSignal Processing, Computer-AssistedHeartHumansImage EnhancementImage Interpretation, Computer-AssistedMagnetic Resonance Imaging, CineModels, BiologicalPhantoms, ImagingReproducibility of ResultsSensitivity and SpecificitySteady-state free precessionT(1) mappingTissue characterizationTransient signal oscillations

Identifiers

PMID25660643
PMCPMC9097815

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.