ArticleMagnetic resonance imaging2015
Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer.
Article in Magnetic resonance imaging, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Free-Breathing Ungated Radial Simultaneous Multi-Slice Cardiac T1 Mapping.Journal of magnetic resonance imaging : JMRI · 2025Article
- Four-angle method for practical ultra-high-resolution magnetic resonance mapping of brain longitudinal relaxation time and apparent proton density.Magnetic resonance imaging · 2020Article
- Towards accurate and precise TMagma (New York, N.Y.) · 2018Review
- Influence of spatial resolution and contrast agent dosage on myocardial T1 relaxation times.Magma (New York, N.Y.) · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
backgroundThe purpose of this work was to evaluate different magnetization preparation and readout sequences for modified Look-Locker inversion recovery (MOLLI) toward improved T1 mapping in the heart. Elements investigated include: catalyzation sequences to prepare the magnetization before readout, alternate k-space trajectories, a spoiled gradient recalled echo readout, and a 5b(3b)3b MOLLI sampling scheme ('b' denoting beats).
methodsConventional 3b(3b)3b(3b)5b MOLLI with a linear k-space trajectory was compared to four variants in simulations, in vitro and in vivo (at 3T). Variants were centric conventional MOLLI, centric-paired conventional MOLLI, linear 5b(3b)3b MOLLI and spoiled gradient recalled echo MOLLI. Each of these was applied with three magnetization catalyzation methods, and T1 measurement accuracy and precision were evaluated in simulations via a Monte Carlo algorithm, in a set of calibrated phantoms, and in ten healthy volunteers. Contrast-to-noise, heart rate dependence and B1+ dependence were also evaluated.
resultsA linear k-space trajectory was superior in vitro to centric and centric-paired trajectories. Of the catalyzation methods, preparation of transverse magnetization only-using a linearly increasing flip angle catalyzation-improved MOLLI T1 measurement accuracy, precision, and map quality versus methods that include catalyzation of the longitudinal magnetization. The 5b(3b)3b MOLLI scheme offered comparable native T1 measurement accuracy and precision to conventional MOLLI, despite its shortened acquisition.
conclusionsMOLLI T1 measurement accuracy, precision, and map quality depend on the method of catalyzation of magnetization prior to image acquisition, as well as on the readout method and MOLLI sampling scheme used.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials