Evidence map›Paper›PMID 25653601›Full record

ArticleFrontiers in systems neuroscience2014

The vestibular implant: frequency-dependency of the electrically evoked vestibulo-ocular reflex in humans.

Raymond van de Berg, Nils Guinand, T A Khoa Nguyen, Maurizio Ranieri, Samuel Cavuscens, Jean-Philippe Guyot, Robert Stokroos, Herman Kingma, Angelica Perez-Fornos

2 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in Frontiers in systems neuroscience, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 47 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed, 1 pooled it
5.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04918745 naactive not recruitingnot on this mapstarted 2021, after this paper: background citation

VertiGO! - Get up and GO! With the Vestibular Implant

TypeinterventionalSponsorMaastricht University Medical CenterRan2021 to 2029Enrolled13ConditionsBilateral Vestibular LossArmsCochlear Vestibular Implant (CVI)
NCT05246553 naunknown statusnot on this map

Electrical Stimulation of the Peripheral Vestibular System in Order to Develop a Vestibular Implant

TypeinterventionalSponsorNils GuinandRan2011 to 2023Enrolled52ConditionsVestibular Disorder, Bilateral Vestibulopathy, Bilateral Vestibular LossArmsElectrical stimulation of the vestibular system, Electrical stimulation of the auditory system, Bilateral vestibulopathy Patients (BV), Unilateral vestibulopathy Patients (UV)
3 · Its place in the literature

Who cites it

47 citing papers in PubMed, 1 synthesis or guideline pooled it, 85 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Review
  12. Vestibular prosthesis: from basic research to clinics.Frontiers in integrative neuroscience · 2023
    Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 3 countries.

Raymond van de BergDivision of Balance Disorders, Department of Otorhinolaryngology and Head and Neck Surgery, Faculty of Health Medicine and Life Sciences, School for Mental Health and Neuroscience, Maastricht University Medical Center Maastricht, Netherlands ; Faculty of Physics, Tomsk State University Tomsk, Russia.
Nils GuinandService of Otorhinolaryngology and Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals Geneva, Switzerland.
T A Khoa NguyenTranslational Neural Engineering Lab, Center for Neuroprosthetics, Interfaculty Institute of Bioengineering, École Polytechnique Fédérale de Lausanne Lausanne, Switzerland.
Maurizio RanieriService of Otorhinolaryngology and Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals Geneva, Switzerland.
Samuel CavuscensService of Otorhinolaryngology and Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals Geneva, Switzerland.
Jean-Philippe GuyotService of Otorhinolaryngology and Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals Geneva, Switzerland.
Robert StokroosDivision of Balance Disorders, Department of Otorhinolaryngology and Head and Neck Surgery, Faculty of Health Medicine and Life Sciences, School for Mental Health and Neuroscience, Maastricht University Medical Center Maastricht, Netherlands.
Herman KingmaDivision of Balance Disorders, Department of Otorhinolaryngology and Head and Neck Surgery, Faculty of Health Medicine and Life Sciences, School for Mental Health and Neuroscience, Maastricht University Medical Center Maastricht, Netherlands ; Faculty of Physics, Tomsk State University Tomsk, Russia.
Angelica Perez-FornosService of Otorhinolaryngology and Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals Geneva, Switzerland.
University Hospital of Geneva · CHMaastricht University · NLNational Research Tomsk State University · RU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The vestibulo-ocular reflex (VOR) shows frequency-dependent behavior. This study investigated whether the characteristics of the electrically evoked VOR (eVOR) elicited by a vestibular implant, showed the same frequency-dependency. Twelve vestibular electrodes implanted in seven patients with bilateral vestibular hypofunction (BVH) were tested. Stimuli consisted of amplitude-modulated electrical stimulation with a sinusoidal profile at frequencies of 0.5, 1, and 2 Hz. The main characteristics of the eVOR were evaluated and compared to the "natural" VOR characteristics measured in a group of age-matched healthy volunteers who were subjected to horizontal whole body rotations with equivalent sinusoidal velocity profiles at the same frequencies. A strong and significant effect of frequency was observed in the total peak eye velocity of the eVOR. This effect was similar to that observed in the "natural" VOR. Other characteristics of the (e)VOR (angle, habituation-index, and asymmetry) showed no significant frequency-dependent effect. In conclusion, this study demonstrates that, at least at the specific (limited) frequency range tested, responses elicited by a vestibular implant closely mimic the frequency-dependency of the "normal" vestibular system.

Indexed as

bilateral vestibular areflexiabilateral vestibulopathyneural prosthesisvestibular implantvestibular prosthesisvestibulo-ocular reflex

Identifiers

PMID25653601
PMCPMC4299437
OpenAlexW1986780754

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.