ArticleMedical physics2015
Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: phantom and patient studies.
Article in Medical physics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 44 citations in OpenAlex.
- TagGen: Diffusion-based generative model for cardiac MR tagging super resolution.Magnetic resonance in medicine · 2025Article
- Conditional diffusion-generated super-resolution for myocardial perfusion MRI.Frontiers in cardiovascular medicine · 2025Article
- Development and first implementation of a novel multi-modality cardiac motion and dosimetry phantom for radiotherapy applications.Medical physics · 2024Article
- Highly accelerated free-breathing real-time myocardial tagging for exercise cardiovascular magnetic resonance.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023Article
- Multimodal phantoms for clinical PET/MRI.EJNMMI physics · 2021Review
- Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2021Review
- MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiacPhysics in medicine and biology · 2019Article
- Advances in imaging instrumentation for nuclear cardiology.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019Review
- A deep Boltzmann machine-driven level set method for heart motion tracking using cine MRI images.Medical image analysis · 2018Article
- MR-based motion correction for cardiac PET parametric imaging: a simulation study.EJNMMI physics · 2018Article
- Motion-corrected simultaneous cardiac positron emission tomography and coronary MR angiography with high acquisition efficiency.Magnetic resonance in medicine · 2018Article
- MR/PET Imaging of the Cardiovascular System.JACC. Cardiovascular imaging · 2017Review
- Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.PET clinics · 2017Review
- Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies.Physics in medicine and biology · 2017Article
- Cardiac and Respiratory Motion Correction for Simultaneous Cardiac PET/MR.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2017Article
- Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR.Physics in medicine and biology · 2017Article
- Feasibility of simultaneous PET-MR perfusion using a novel cardiac perfusion phantom.European journal of hybrid imaging · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 5 institutions in 1 country.
Funding
Abstract
purposeDegradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data.
methodsFully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction.
resultsAlthough tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction.
conclusionsAccelerated tMR images obtained with more than 4 times acceleration can still provide relatively accurate motion fields and yield tMR-based motion corrected PET images with similar image quality as those reconstructed using fully sampled tMR data. The reduction of tMR acquisition time makes it more compatible with routine clinical cardiac PET-MR studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.