Evidence map›Paper›PMID 25652521›Full record

ArticleMedical physics2015

Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: phantom and patient studies.

Chuan Huang, Yoann Petibon, Jinsong Ouyang, Timothy G Reese, Mark A Ahlman, David A Bluemke, Georges El Fakhri

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
6.5field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 44 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Highly accelerated free-breathing real-time myocardial tagging for exercise cardiovascular magnetic resonance.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Article
  5. Review
  6. Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2021
    Review
  7. Article
  8. Advances in imaging instrumentation for nuclear cardiology.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019
    Review
  9. Article
  10. Article
  11. Article
  12. MR/PET Imaging of the Cardiovascular System.JACC. Cardiovascular imaging · 2017
    Review
  13. Review
  14. Article
  15. Cardiac and Respiratory Motion Correction for Simultaneous Cardiac PET/MR.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2017
    Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Chuan HuangCenter for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114; Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115; and Departments of Radiology, Psychiatry, Stony Brook Medicine, Stony Brook, New York 11794.
Yoann PetibonCenter for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114.
Jinsong OuyangCenter for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 and Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115.
Timothy G ReeseDepartment of Radiology, Harvard Medical School, Boston, Massachusetts 02115 and Martinos Center for Biomedical Imaging, Charlestown, Massachusetts 02129.
Mark A AhlmanRadiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, Maryland 20892.
David A BluemkeRadiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, Maryland 20892.
Georges El FakhriCenter for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 and Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115.
Massachusetts General Hospital · USNational Institutes of Health Clinical Center · USGordon Center for Medical Imaging · USHarvard University · USHealth First · US

Funding

Project 4P41EB015896 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI ROSEN, BRUCE R · 2012 to 2018
$9.8M
Molecular Biomedical Imaging Laboratory (NIBIB)ZIAEB000072 · NIBIB · NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING · PI BLUEMKE, DAVID · 2010 to 2017
$5.0M
Quantitative Oncologic PET-MRR01CA165221 · NCI · MASSACHUSETTS GENERAL HOSPITAL · PI EL FAKHRI, GEORGES · 2012 to 2023
$4.7M
Quantitative Simultaneous Cardiac PET-MRR01HL118261 · NHLBI · MASSACHUSETTS GENERAL HOSPITAL · PI OUYANG, JINSONG · 2014 to 2018
$2.6M
Quantitative Cardiac PETR01HL110241 · NHLBI · MASSACHUSETTS GENERAL HOSPITAL · PI EL FAKHRI, GEORGES · 2011 to 2014
$1.9M
Motion Compensation in Simultaneous PET-MRR21EB012326 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI EL FAKHRI, GEORGES · 2010 to 2011
$470k
Molecular Biomedical Imaging Laboratory (CC)ZIACL090019 · CLC · CLINICAL CENTER · PI JONES, ELIZABETH C. · 2010 to 2017
$0k
Intramural NIH HHSNCI NIH HHS R01 CA165221NCI NIH HHS R01-CA165221NHLBI NIH HHS R01 HL110241NHLBI NIH HHS R01-HL110241NHLBI NIH HHS R01 HL118261NHLBI NIH HHS R01-HL118261NIBIB NIH HHS P41 EB015896NIBIB NIH HHS P41-EB015896NIBIB NIH HHS R21 EB012326NIBIB NIH HHS R21-EB012326
6 · The paper itself

Abstract

purposeDegradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data.

methodsFully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction.

resultsAlthough tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction.

conclusionsAccelerated tMR images obtained with more than 4 times acceleration can still provide relatively accurate motion fields and yield tMR-based motion corrected PET images with similar image quality as those reconstructed using fully sampled tMR data. The reduction of tMR acquisition time makes it more compatible with routine clinical cardiac PET-MR studies.

Indexed as

MovementPhantoms, ImagingHeartHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingPositron-Emission TomographyTime Factors

Identifiers

PMID25652521
PMCPMC4312342
OpenAlexW2042034732

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked