Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters.

Steven T Bache, Titania Juang, Matthew D Belley, Bridget F Koontz, John Adamovics, Terry T Yoshizumi, David G Kirsch, Mark Oldham

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
7.8field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Detection of therapeutic radiation in three-dimensions.Beilstein journal of organic chemistry · 2017
    Review
  8. Review
  9. Article
  10. Novel technique for high-precision stereotactic irradiation of mouse brains.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2016
    Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Steven T BacheDuke University Medical Physics Graduate Program, Durham, North Carolina 27705.
Titania JuangDuke University Medical Physics Graduate Program, Durham, North Carolina 27705.
Matthew D BelleyDuke University Medical Physics Graduate Program, Durham, North Carolina 27705.
Bridget F KoontzDuke University Medical Center, Durham, North Carolina 27710.
John AdamovicsRider University, Lawrenceville, New Jersey 08648.
Terry T YoshizumiDuke University Medical Center, Durham, North Carolina 27710.
David G KirschDuke University Medical Center, Durham, North Carolina 27710.
Mark OldhamDuke University Medical Center, Durham, North Carolina 27710.
Duke University · USDuke University Hospital · USDuke Medical Center · USRider University · US

Funding

Somatostatin analogues as countermeasures against intestinal radiation toxicityU19AI067798 · NIAID · DUKE UNIVERSITY · PI CHAO, NELSON J. · 2005 to 2024
$82.1M
Accurate, High Resolution 3D Dosimetry.R01CA100835 · NCI · WILLIAM BEAUMONT HOSPITAL RESEARCH INST · PI OLDHAM, MARK · 2003 to 2012
$2.3M
NCI NIH HHS R01 CA100835NIAID NIH HHS 5U19AI067798NIAID NIH HHS U19 AI067798
6 · The paper itself

Abstract

purposeSophisticated small animal irradiators, incorporating cone-beam-CT image-guidance, have recently been developed which enable exploration of the efficacy of advanced radiation treatments in the preclinical setting. Microstereotactic-body-radiation-therapy (microSBRT) is one technique of interest, utilizing field sizes in the range of 1-15 mm. Verification of the accuracy of microSBRT treatment delivery is challenging due to the lack of available methods to comprehensively measure dose distributions in representative phantoms with sufficiently high spatial resolution and in 3 dimensions (3D). This work introduces a potential solution in the form of anatomically accurate rodent-morphic 3D dosimeters compatible with ultrahigh resolution (0.3 mm(3)) optical computed tomography (optical-CT) dose read-out.

methodsRodent-morphic dosimeters were produced by 3D-printing molds of rodent anatomy directly from contours defined on x-ray CT data sets of rats and mice, and using these molds to create tissue-equivalent radiochromic 3D dosimeters from Presage. Anatomically accurate spines were incorporated into some dosimeters, by first 3D printing the spine mold, then forming a high-Z bone equivalent spine insert. This spine insert was then set inside the tissue equivalent body mold. The high-Z spinal insert enabled representative cone-beam CT IGRT targeting. On irradiation, a linear radiochromic change in optical-density occurs in the dosimeter, which is proportional to absorbed dose, and was read out using optical-CT in high-resolution (0.5 mm isotropic voxels). Optical-CT data were converted to absolute dose in two ways: (i) using a calibration curve derived from other Presage dosimeters from the same batch, and (ii) by independent measurement of calibrated dose at a point using a novel detector comprised of a yttrium oxide based nanocrystalline scintillator, with a submillimeter active length. A microSBRT spinal treatment was delivered consisting of a 180° continuous arc at 225 kVp with a 20 × 10 mm field size. Dose response was evaluated using both the Presage/optical-CT 3D dosimetry system described above, and independent verification in select planes using EBT2 radiochromic film placed inside rodent-morphic dosimeters that had been sectioned in half.

resultsRodent-morphic 3D dosimeters were successfully produced from Presage radiochromic material by utilizing 3D printed molds of rat CT contours. The dosimeters were found to be compatible with optical-CT dose readout in high-resolution 3D (0.5 mm isotropic voxels) with minimal artifacts or noise. Cone-beam CT image guidance was possible with these dosimeters due to sufficient contrast between high-Z spinal inserts and tissue equivalent Presage material (CNR ∼10 on CBCT images). Dose at isocenter measured with optical-CT was found to agree with nanoscintillator measurement to within 2.8%. Maximum dose in line profiles taken through Presage and film dose slices agreed within 3%, with FWHM measurements through each profile found to agree within 2%.

conclusionsThis work demonstrates the feasibility of using 3D printing technology to make anatomically accurate Presage rodent-morphic dosimeters incorporating spinal-mimicking inserts. High quality optical-CT 3D dosimetry is feasible on these dosimeters, despite the irregular surfaces and implanted inserts. The ability to measure dose distributions in anatomically accurate phantoms represents a powerful useful additional verification tool for preclinical microSBRT.

Indexed as

Printing, Three-DimensionalAnimalsCone-Beam Computed TomographyMiceNanotechnologyPhantoms, ImagingRadiometryRadiosurgeryRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRatsSurgery, Computer-Assisted

Identifiers

PMID25652497
PMCPMC4304963
OpenAlexW2090788189

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.