Evidence map›Paper›PMID 25644059›Full record

ArticleMedical & biological engineering & computing2015

Improved robust T-wave alternans detectors.

O Meste, D Janusek, S Karczmarewicz, A Przybylski, M Kania, A Maciag, R Maniewski

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

O MesteLaboratoire I3S UNS-CNRS UMR7172, Université de Nice-Sophia Antipolis, 2000 route des lucioles Les Algorithmes - bt. Euclide B, CS 40121, 06903, Sophia Antipolis Cedex, France, meste@i3s.unice.fr.
D Janusek
S Karczmarewicz
A Przybylski
M Kania
A Maciag
R Maniewski

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

New statistical and spectral detectors, the modified matched pairs t test, the extended spectral method and the modified spectral method, were proposed for T-wave alternans (TWA) detection gaining robustness according to trend and single-frequency interferences. They were compared to classic detectors such as matched pairs t test, unpaired t test, spectral method, generalized likelihood ratio test and estimated TWA amplitude within a simulation framework and applied to real data. The optimal detection threshold was selected by using a full Monte-Carlo simulation where signals, with and without alternans episodes, were corrupted by Gaussian noise with different power and single-frequency interferences with different tones. All the combinations of noise and frequency were selected and repeated 500 times in order to compute probability of detection ([Formula: see text]) and the false alarm probability ([Formula: see text]), providing ROC curves. The study group consisted of 50 patients with implantable cardioverter-defibrillator (age: [Formula: see text]; LVEF: [Formula: see text]), who were paced (ventricular pacing) at 100 bpm. Two-minute recordings were analyzed. The XYZ orthogonal lead system was used. The best performance was reached by using the modified matched pairs t test (in comparison with the spectral method and other reference methods).

Indexed as

Signal Processing, Computer-AssistedAgedArrhythmias, CardiacDefibrillators, ImplantableElectrocardiographyElectrodesFemaleHumansMaleMiddle Aged

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.