Evidence map›Paper›PMID 25643953›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2015

Assessment of global longitudinal strain using standardized myocardial deformation imaging: a modality independent software approach.

Johannes H Riffel, Marius G P Keller, Matthias Aurich, Yannick Sander, Florian Andre, Sorin Giusca, Fabian Aus dem Siepen, Sebastian Seitz, Christian Galuschky, Grigorios Korosoglou and 3 more

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Prognostic value of novel imaging parameters derived from standard cardiovascular magnetic resonance in high risk patients with systemic light chain amyloidosis.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2019
    Article
  10. Article
  11. Unusual case of ATTR amyloidosis with cardiac manifestation and situs inversus totalis.Clinical research in cardiology : official journal of the German Cardiac Society · 2017
    Article
  12. Diagnostic value of speckle-tracking echocardiography in confirmed cardiac sarcoidosis.Clinical research in cardiology : official journal of the German Cardiac Society · 2016
    Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Johannes H RiffelDepartment of Cardiology, University of Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
Marius G P Keller
Matthias Aurich
Yannick Sander
Florian Andre
Sorin Giusca
Fabian Aus dem Siepen
Sebastian Seitz
Christian Galuschky
Grigorios Korosoglou
Derliz Mereles
Hugo A Katus
Sebastian J Buss

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMyocardial deformation measurement is superior to left ventricular ejection fraction in identifying early changes in myocardial contractility and prediction of cardiovascular outcome. The lack of standardization hinders its clinical implementation. The aim of the study is to investigate a novel standardized deformation imaging approach based on the feature tracking algorithm for the assessment of global longitudinal (GLS) and global circumferential strain (GCS) in echocardiography and cardiac magnetic resonance imaging (CMR).

methods70 subjects undergoing CMR were consecutively investigated with echocardiography within a median time of 30 min. GLS and GCS were analyzed with a post-processing software incorporating the same standardized algorithm for both modalities. Global strain was defined as the relative shortening of the whole endocardial contour length and calculated according to the strain formula.

resultsMean GLS values were -16.2 ± 5.3 and -17.3 ± 5.3 % for echocardiography and CMR, respectively. GLS did not differ significantly between the two imaging modalities, which showed strong correlation (r = 0.86), a small bias (-1.1 %) and narrow 95 % limits of agreement (LOA ± 5.4 %). Mean GCS values were -17.9 ± 6.3 and -24.4 ± 7.8 % for echocardiography and CMR, respectively. GCS was significantly underestimated by echocardiography (p < 0.001). A weaker correlation (r = 0.73), a higher bias (-6.5 %) and wider LOA (± 10.5 %) were observed for GCS. GLS showed a strong correlation (r = 0.92) when image quality was good, while correlation dropped to r = 0.82 with poor acoustic windows in echocardiography. GCS assessment revealed only a strong correlation (r = 0.87) when echocardiographic image quality was good. No significant differences for GLS between two different echocardiographic vendors could be detected.

conclusionsQuantitative assessment of GLS using a standardized software algorithm allows the direct comparison of values acquired irrespective of the imaging modality. GLS may, therefore, serve as a reliable parameter for the assessment of global left ventricular function in clinical routine besides standard evaluation of the ejection fraction.

Indexed as

AlgorithmsSoftwareCompressive StrengthEchocardiographyElasticity Imaging TechniquesElastic ModulusFemaleHumansImage Interpretation, Computer-AssistedMagnetic Resonance Imaging, CineMaleMiddle AgedReproducibility of ResultsSensitivity and SpecificityStress, MechanicalStroke Volume

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.