ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2015
Two-dimensional shear-wave elastography on conventional ultrasound scanners with time-aligned sequential tracking (TAST) and comb-push ultrasound shear elastography (CUSE).
Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
47 citing papers in PubMed, 106 citations in OpenAlex.
- Effects of fentanyl on diaphragm muscle force in patients undergoing knee arthroplasty: a randomised double-blind clinical trial.British journal of anaesthesia · 2026Trial
- Observations of blue-stripe artefacts in 2D SWE not reported in guidelines and their influence on diagnostic accuracy-A technical note.Radiology case reports · 2026Article
- AutoSOUL: Deep Convolutional Neural Network for Autonomous Selection of Ultrasound Speckle Tracking Parameters.IEEE transactions on ultrasonics · 2026Article
- Three-Dimensional Shear-Wave Viscoelastographic Estimation by System Identification for Prostate Cancer Localization.Ultrasound in medicine & biology · 2025Article
- Shear wave elastography primer for the abdominal radiologist.Abdominal radiology (New York) · 2025Review
- Estimation of the phase velocity dispersion curves for viscoelastic materials using Point Limited Shear Wave Elastography.Ultrasonics · 2025Article
- Four-Dimensional (4D) Ultrasound Shear Wave Elastography Using Sequential Excitation.IEEE transactions on bio-medical engineering · 2025Article
- Attenuation Measuring Ultrasound Shearwave Elastography (AMUSE) as Noninvasive Imaging Biomarker for Liver Acute Cellular Rejection.Ultrasound in medicine & biology · 2025Article
- SELFNet: Denoising Shear Wave Elastography Using Spatial-temporal Fourier Feature Networks.Ultrasound in medicine & biology · 2024Article
- Acoustic diffraction-resistant adaptive profile technology (ADAPT) for elasticity imaging.Science advances · 2023Article
- Comb Detection for Measuring Shear Wave Propagation.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2023Article
- High-Volume-Rate 3-D Ultrasound Imaging Using Fast-Tilting and Redirecting Reflectors.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2023Article
- A Non-invasive Method to Estimate the Stress-Strain Curve of Soft Tissue Using Ultrasound Elastography.Ultrasound in medicine & biology · 2022Article
- Quantitative Shear Wave Speed Assessment for Muscles With the Diagnosis of Taut Bands and/or Myofascial Trigger Points Using Probe Oscillation Shear Wave Elastography: A Pilot Study.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2022Article
- Hybrid high-definition microvessel imaging/shear wave elastography improves breast lesion characterization.Breast cancer research : BCR · 2022Article
- Three-Dimensional Shear Wave Elastography Using a 2D Row Column Addressing (RCA) Array.BME frontiers · 2022Article
- Speed of sound and shear wave speed for calf soft tissue composition and nonlinearity assessment.Quantitative imaging in medicine and surgery · 2021Article
- Time-Aligned Plane Wave Compounding Methods for High-Frame-Rate Shear Wave Elastography: Experimental Validation and Performance Assessment on Tissue Phantoms.Ultrasound in medicine & biology · 2021Article
- Viscoelastic parameter estimation using simulated shear wave motion and convolutional neural networks.Computers in biology and medicine · 2021Article
- Liraglutide reduces attenuation coefficient as a measure of hepatic steatosis during 16 weeks' treatment in nondiabetic obese patients: A pilot trial.JGH open : an open access journal of gastroenterology and hepatology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 3 institutions in 2 countries.
Funding
Abstract
Two-dimensional shear-wave elastography presents 2-D quantitative shear elasticity maps of tissue, which are clinically useful for both focal lesion detection and diffuse disease diagnosis. Realization of 2-D shear-wave elastography on conventional ultrasound scanners, however, is challenging because of the low tracking pulse-repetition-frequency (PRF) of these systems. Although some clinical and research platforms support software beamforming and plane-wave imaging with high PRF, the majority of current clinical ultrasound systems do not have the software beamforming capability, which presents a critical challenge for translating the 2-D shear-wave elastography technique from laboratory to clinical scanners. To address this challenge, this paper presents a time-aligned sequential tracking (TAST) method for shear-wave tracking on conventional ultrasound scanners. TAST takes advantage of the parallel beamforming capability of conventional systems and realizes high-PRF shear-wave tracking by sequentially firing tracking vectors and aligning shear wave data in the temporal direction. The comb-push ultrasound shear elastography (CUSE) technique was used to simultaneously produce multiple shear wave sources within the field-of-view (FOV) to enhance shear wave SNR and facilitate robust reconstructions of 2-D elasticity maps. TAST and CUSE were realized on a conventional ultrasound scanner. A phantom study showed that the shear-wave speed measurements from the conventional ultrasound scanner were in good agreement with the values measured from other 2-D shear wave imaging technologies. An inclusion phantom study showed that the conventional ultrasound scanner had comparable performance to a state-of-the-art shear-wave imaging system in terms of bias and precision in measuring different sized inclusions. Finally, in vivo case analysis of a breast with a malignant mass, and a liver from a healthy subject demonstrated the feasibility of using the conventional ultrasound scanner for in vivo 2-D shear-wave elastography. These promising results indicate that the proposed technique can enable the implementation of 2-D shear-wave elastography on conventional ultrasound scanners and potentially facilitate wider clinical applications with shear-wave elastography.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.