Evidence map›Paper›PMID 25631270›Full record

ArticleJournal of materials science. Materials in medicine2015

Osseointegration improvement by plasma electrolytic oxidation of modified titanium alloys surfaces.

Mónica Echeverry-Rendón, Oscar Galvis, David Quintero Giraldo, Juan Pavón, José Luis López-Lacomba, Emilio Jiménez-Piqué, Marc Anglada, Sara M Robledo, Juan G Castaño, Félix Echeverría

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of materials science. Materials in medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Mónica Echeverry-RendónPrograma de Estudio y Control de Enfermedades Tropicales (PECET), Instituto de Investigaciones Médicas, Facultad de Medicina, Universidad de Antioquia, Calle 70 No. 52-21, Medellín, Colombia, monica.echeverry@udea.edu.co.
Oscar Galvis
David Quintero Giraldo
Juan Pavón
José Luis López-Lacomba
Emilio Jiménez-Piqué
Marc Anglada
Sara M Robledo
Juan G Castaño
Félix Echeverría

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Titanium (Ti) is a material frequently used in orthopedic applications, due to its good mechanical properties and high corrosion resistance. However, formation of a non-adherent fibrous tissue between material and bone drastically could affect the osseointegration process and, therefore, the mechanical stability of the implant. Modifications of topography and configuration of the tissue/material interface is one of the mechanisms to improve that process by manipulating parameters such as morphology and roughness. There are different techniques that can be used to modify the titanium surface; plasma electrolytic oxidation (PEO) is one of those alternatives, which consists of obtaining porous anodic coatings by controlling parameters such as voltage, current, anodizing solution and time of the reaction. From all of the above factors, and based on previous studies that demonstrated that bone cells sense substrates features to grow new tissue, in this work commercially pure Ti (c.p Ti) and Ti6Al4V alloy samples were modified at their surface by PEO in different anodizing solutions composed of H2SO4 and H3PO4 mixtures. Treated surfaces were characterized and used as platforms to grow osteoblasts; subsequently, cell behavior parameters like adhesion, proliferation and differentiation were also studied. Although the results showed no significant differences in proliferation, differentiation and cell biological activity, overall results showed an important influence of topography of the modified surfaces compared with polished untreated surfaces. Finally, this study offers an alternative protocol to modify surfaces of Ti and their alloys in a controlled and reproducible way in which biocompatibility of the material is not compromised and osseointegration would be improved.

Indexed as

AlloysAnimalsCell AdhesionCell DifferentiationCell LineCell ProliferationCoated Materials, BiocompatibleElectrolysisHumansMaterials TestingMiceOsseointegrationOsteoblastsOxidation-ReductionPlasma GasesRatsAlloysCoated Materials, BiocompatiblePlasma GasesTitaniumtitanium alloy (TiAl6V4)

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.