ArticleJournal of materials science. Materials in medicine2015
Osseointegration improvement by plasma electrolytic oxidation of modified titanium alloys surfaces.
Article in Journal of materials science. Materials in medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Beyond microroughness: novel approaches to navigate osteoblast activity on implant surfaces.International journal of implant dentistry · 2024Review
- Nonthermal Atmospheric Pressure Plasma Treatment of Endosteal Implants for Osseointegration and Antimicrobial Efficacy: A Comprehensive Review.Bioengineering (Basel, Switzerland) · 2024Review
- Influence of Femtosecond Laser Modification on Biomechanical and Biofunctional Behavior of Porous Titanium Substrates.Materials (Basel, Switzerland) · 2022Article
- Electrical Impedance of Surface Modified Porous Titanium Implants with Femtosecond Laser.Materials (Basel, Switzerland) · 2022Article
- Research progress on the biological modifications of implant materials in 3D printed intervertebral fusion cages.Journal of materials science. Materials in medicine · 2021Review
- Novel Mg-Incorporated Micro-Arc Oxidation Coatings for Orthopedic Implants Application.Materials (Basel, Switzerland) · 2021Article
- Influence of Process Parameters on the Tribological Behavior of PEO Coatings on CP-Titanium 4+ Alloys for Biomedical Applications.Materials (Basel, Switzerland) · 2021Article
- Inorganic Agents for Enhanced Angiogenesis of Orthopedic Biomaterials.Advanced healthcare materials · 2021Review
- Additive manufacturing of Ti6Al4V alloy via electron beam melting for the development of implants for the biomedical industry.Heliyon · 2021Review
- 3D Titania Nanofiber-Like Webs Induced by Plasma Ionization: A New Direction for Bioreactivity and Osteoinductivity Enhancement of Biomaterials.Scientific reports · 2019Article
- Evaluation of the osteogenesis and osseointegration of titanium alloys coated with graphene: an in vivo study.Scientific reports · 2018Article
- Modification of titanium alloys surface properties by plasma electrolytic oxidation (PEO) and influence on biological response.Journal of materials science. Materials in medicine · 2017Article
- Effects of negatively and positively charged Ti metal surfaces on ceramic coating adhesion and cell response.Journal of materials science. Materials in medicine · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Titanium (Ti) is a material frequently used in orthopedic applications, due to its good mechanical properties and high corrosion resistance. However, formation of a non-adherent fibrous tissue between material and bone drastically could affect the osseointegration process and, therefore, the mechanical stability of the implant. Modifications of topography and configuration of the tissue/material interface is one of the mechanisms to improve that process by manipulating parameters such as morphology and roughness. There are different techniques that can be used to modify the titanium surface; plasma electrolytic oxidation (PEO) is one of those alternatives, which consists of obtaining porous anodic coatings by controlling parameters such as voltage, current, anodizing solution and time of the reaction. From all of the above factors, and based on previous studies that demonstrated that bone cells sense substrates features to grow new tissue, in this work commercially pure Ti (c.p Ti) and Ti6Al4V alloy samples were modified at their surface by PEO in different anodizing solutions composed of H2SO4 and H3PO4 mixtures. Treated surfaces were characterized and used as platforms to grow osteoblasts; subsequently, cell behavior parameters like adhesion, proliferation and differentiation were also studied. Although the results showed no significant differences in proliferation, differentiation and cell biological activity, overall results showed an important influence of topography of the modified surfaces compared with polished untreated surfaces. Finally, this study offers an alternative protocol to modify surfaces of Ti and their alloys in a controlled and reproducible way in which biocompatibility of the material is not compromised and osseointegration would be improved.
Indexed as
Identifiers
25631270What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.