Evidence map›Paper›PMID 25627310›Full record

ArticleJournal of neural engineering2015

Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees.

Daniel W Tan, Matthew A Schiefer, Michael W Keith, J Robert Anderson, Dustin J Tyler

Open access · greenAbstract read
In one paragraph

Article in Journal of neural engineering, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 92 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
92citing papers in PubMed, 1 pooled it
9.1field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

92 citing papers in PubMed, 1 synthesis or guideline pooled it, 175 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Review
  13. Clinical Applications and Future Translation of Somatosensory Neuroprostheses.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2024
    Review
  14. Phantom limb syndrome: from pathogenesis to treatment. A narrative review.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2024
    Review
  15. Article
  16. Article
  17. Review
  18. Article
  19. Cortical Reorganization after Limb Loss: Bridging the Gap between Basic Science and Clinical Recovery.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2024
    Review
  20. Article

32 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Daniel W TanLouis Stokes Cleveland Department of Veterans Affairs Medical Center, Cleveland, OH 44106, USA. Case Western Reserve University, Cleveland, OH 44106, USA.
Matthew A Schiefer
Michael W Keith
J Robert Anderson
Dustin J Tyler
Case Western Reserve University · USMetroHealth · USRainbow Babies & Children's Hospital · USUnited States Department of Veterans Affairs · US

Funding

Peripheral Interfaces in Amputees to Restore SensationI01RX001334 · VA · LOUIS STOKES CLEVELAND VA MEDICAL CENTER · PI TYLER, DUSTIN J. · 2015 to 2018
–
RRD VA I01 RX001334
6 · The paper itself

Abstract

objectiveStability and selectivity are important when restoring long-term, functional sensory feedback in individuals with limb-loss. Our objective is to demonstrate a chronic, clinical neural stimulation system for providing selective sensory response in two upper-limb amputees. APPROACH: Multi-contact cuff electrodes were implanted in the median, ulnar, and radial nerves of the upper-limb. MAIN

resultsNerve stimulation produced a selective sensory response on 19 of 20 contacts and 16 of 16 contacts in subjects 1 and 2, respectively. Stimulation elicited multiple, distinct percept areas on the phantom and residual limb. Consistent threshold, impedance, and percept areas have demonstrated that the neural interface is stable for the duration of this on-going, chronic study. SIGNIFICANCE: We have achieved selective nerve response from multi-contact cuff electrodes by demonstrating characteristic percept areas and thresholds for each contact. Selective sensory response remains consistent in two upper-limb amputees for 1 and 2 years, the longest multi-contact sensory feedback system to date. Our approach demonstrates selectivity and stability can be achieved through an extraneural interface, which can provide sensory feedback to amputees.

Indexed as

Electrodes, ImplantedSensationAmputeesArmElectric Stimulation TherapyEquipment DesignEquipment Failure AnalysisHumansMaleMiddle AgedPeripheral NervesReproducibility of ResultsSensitivity and Specificity

Identifiers

PMID25627310
PMCPMC5517311
OpenAlexW2131130558

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.