Evidence map›Paper›PMID 25620906›Full record

ArticleFrontiers in neuroscience2014

High-resolution diffusion kurtosis imaging at 3T enabled by advanced post-processing.

Siawoosh Mohammadi, Karsten Tabelow, Lars Ruthotto, Thorsten Feiweier, Jörg Polzehl, Nikolaus Weiskopf

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neuroscience, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
3.5field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 3 countries.

Siawoosh MohammadiWellcome Trust Centre for Neuroimaging, UCL Institute of Neurology, University College London London, UK ; Department of Systems Neuroscience, University Medical Center Hamburg-Eppendorf Hamburg, Germany.
Karsten TabelowStochastic Algorithms and Nonparametric Statistics, Weierstrass Institute for Applied Analysis and Stochastics Berlin, Germany.
Lars RuthottoDepartment of Earth, Ocean and Atmospheric Sciences, The University of British Columbia Vancouver, BC, Canada.
Thorsten FeiweierHealthcare Sector, Siemens AG Erlangen, Germany.
Jörg PolzehlStochastic Algorithms and Nonparametric Statistics, Weierstrass Institute for Applied Analysis and Stochastics Berlin, Germany.
Nikolaus WeiskopfWellcome Trust Centre for Neuroimaging, UCL Institute of Neurology, University College London London, UK.
Weierstrass Institute for Applied Analysis and Stochastics · DESiemens Healthcare (Germany) · DEUniversity College London · GBUniversity of British Columbia · CAWellcome Centre for Human Neuroimaging · GB

Funding

Wellcome Trust 091593
6 · The paper itself

Abstract

Diffusion Kurtosis Imaging (DKI) is more sensitive to microstructural differences and can be related to more specific micro-scale metrics (e.g., intra-axonal volume fraction) than diffusion tensor imaging (DTI), offering exceptional potential for clinical diagnosis and research into the white and gray matter. Currently DKI is acquired only at low spatial resolution (2-3 mm isotropic), because of the lower signal-to-noise ratio (SNR) and higher artifact level associated with the technically more demanding DKI. Higher spatial resolution of about 1 mm is required for the characterization of fine white matter pathways or cortical microstructure. We used restricted-field-of-view (rFoV) imaging in combination with advanced post-processing methods to enable unprecedented high-quality, high-resolution DKI (1.2 mm isotropic) on a clinical 3T scanner. Post-processing was advanced by developing a novel method for Retrospective Eddy current and Motion ArtifacT Correction in High-resolution, multi-shell diffusion data (REMATCH). Furthermore, we applied a powerful edge preserving denoising method, denoted as multi-shell orientation-position-adaptive smoothing (msPOAS). We demonstrated the feasibility of high-quality, high-resolution DKI and its potential for delineating highly myelinated fiber pathways in the motor cortex. REMATCH performs robustly even at the low SNR level of high-resolution DKI, where standard EC and motion correction failed (i.e., produced incorrectly aligned images) and thus biased the diffusion model fit. We showed that the combination of REMATCH and msPOAS increased the contrast between gray and white matter in mean kurtosis (MK) maps by about 35% and at the same time preserves the original distribution of MK values, whereas standard Gaussian smoothing strongly biases the distribution.

Indexed as

adaptive smoothingdiffusion kurtosisDKIDTIeddy current and motion artifactsgray matterhigh-resolutionmulti-shell dMRI

Identifiers

PMID25620906
PMCPMC4285740
OpenAlexW2053610521

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.