Evidence map›Paper›PMID 25612849›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2015

Construct stability of an instrumented 2-level cervical corpectomy model following fatigue testing: biomechanical comparison of circumferential antero-posterior instrumentation versus a novel anterior-only transpedicular screw-plate fixation technique.

Heiko Koller, Werner Schmoelz, Juliane Zenner, Alexander Auffarth, Herbert Resch, Wolfgang Hitzl, Davud Malekzadeh, Lukas Ernstbrunner, Martina Blocher, Michael Mayer

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
2.7field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 34 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Progress of the Anterior Transpedicular Screw in Lower Cervical Spine: A Review.Medical science monitor : international medical journal of experimental and clinical research · 2019
    Review
  12. Article
  13. Article
  14. Accuracy of 3D fluoro-navigated anterior transpedicular screws in the subaxial cervical spine: an experimental study on human specimens.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2017
    Article
  15. Cement-augmented screws in a cervical two-level corpectomy with anterior titanium mesh cage reconstruction: a biomechanical study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2017
    Article
  16. Biomechanical testing of circumferential instrumentation after cervical multilevel corpectomy.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 2 countries.

Heiko KollerGerman Scoliosis Center Bad Wildungen, Werner-Wicker-Klinik, Im Kreuzfeld 4, 34537, Bad Wildungen, Germany. heiko.koller@t-online.de.
Werner SchmoelzDepartment of Trauma Surgery, Medical University Innsbruck, Innsbruck, Austria.
Juliane ZennerDepartment for Traumatology and Orthopedic Surgery, Stadtkrankenhaus Korbach, Korbach, Germany.
Alexander AuffarthDepartment for Traumatology and Sports Injuries, Paracelsus Medical University, Salzburg, Austria.
Herbert ReschDepartment for Traumatology and Sports Injuries, Paracelsus Medical University, Salzburg, Austria.
Wolfgang HitzlResearch Office, Biostatistics, Paracelsus Medical University, Salzburg, Austria.
Davud MalekzadehDepartment of Trauma Surgery, Medical University Innsbruck, Innsbruck, Austria.
Lukas ErnstbrunnerDepartment for Traumatology and Sports Injuries, Paracelsus Medical University, Salzburg, Austria.
Martina BlocherDepartment for Traumatology and Sports Injuries, Paracelsus Medical University, Salzburg, Austria.
Michael MayerGerman Scoliosis Center Bad Wildungen, Werner-Wicker-Klinik, Im Kreuzfeld 4, 34537, Bad Wildungen, Germany.
Paracelsus Medical University · ATInnsbruck Medical University · ATWerner-Wicker-Klinik · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionA high rate of complications in multilevel cervical surgery with corpectomies and anterior-only screw-and-plate stabilization is reported. A 360°-instrumentation improves construct stiffness and fusion rates, but adds the morbidity of a second approach. A novel ATS-technique (technique that used anterior transpedicular screw placement) was recently described, yet no study to date has analyzed its performance after fatigue loading. Accordingly, the authors performed an analysis of construct stiffness after fatigue testing of a cervical 2-level corpectomy model reconstructed using a novel anterior transpedicular screw-and-plate technique (ATS-group) in comparison to standard antero-posterior instrumentation (360°-group). MATERIALS AND

methodsTwelve fresh-frozen human cervical spines were mounted on a spine motion tester to analyze restriction of ROM under loading (1.5 Nm) in flexion-extension (FE), axial rotation (AR), and lateral bending (LB). Testing was performed in the intact state, and after instrumentation of a 2-level corpectomy C4 + C5 using a cage and the constructs of ATS- and 360°-group, after 1,000 cycles, and after 2,000 cycles of fatigue testing. In the ATS-group (n = 6), instrumentation was achieved using a customized C3-C6 ATS-plate system. In the 360°-group (n = 6), instrumentation consisted of a standard anterior screw-and-plate system with a posterior instrumentation using C3-C6 lateral mass screws. Motion data were assessed as degrees and further processed as normalized values after standardization to the intact ROM state.

resultsSpecimen age and BMD were not significantly different between the ATS- and 360°-groups. After instrumentation and 2,000 cycles of testing, no specimen exhibited a ROM greater than in the intact state. No specimen exhibited catastrophic construct failure after 2,000 cycles. Construct stiffness in the 360°-group was significantly increased compared to the ATS-group for all loading conditions, except for FE-testing after instrumentation. After 2,000 cycles, restriction of ROM under loading in FE was 39.8 ± 30% in the ATS-group vs. 2.8 ± 2.3% in the 360°-group, in AR 60.4 ± 25.8 vs 15 ± 11%, and in LB 40 ± 23.4 vs 3.9 ± 1.2%. Differences were significant (p < 0.05).

conclusion360°-instrumentation resembles the biomechanical standard of reference for stabilization of 2-level corpectomies. An ATS-construct was also shown to confer high construct stiffness, significantly reducing the percentage ROM beyond that of an intact specimen after 2,000 cycles. This type of instrumentation might be a clinical valuable and biomechanically sound adjunct to multilevel anterior surgical procedures.

Indexed as

Bone PlatesBone ScrewsMaterials TestingAgedBiomechanical PhenomenaCadaverCervical VertebraeDecompression, SurgicalHumansMaleMiddle Aged360° instrumentationAnterior transpedicularBiomechanical testingCervical spineCorpectomyCyclic loading

Identifiers

PMID25612849
OpenAlexW2032803259

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.