Evidence map›Paper›PMID 25606553›Full record

ArticleJoints

Long-term outcome of low contact stress total knee arthroplasty with different mobile bearing designs.

Giuseppe Solarino, Antonio Spinarelli, Massimiliano Carrozzo, Andrea Piazzolla, Giovanni Vicenti, Biagio Moretti

Abstract read
In one paragraph

Article in Joints. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Temporal patterns of commonly used clinical outcome scales during a 5-year period after total knee arthroplasty.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2019
    Article
  5. Article
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Giuseppe SolarinoOrthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari "Aldo Moro", Bari, Italy.
Antonio SpinarelliOrthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari "Aldo Moro", Bari, Italy.
Massimiliano CarrozzoOrthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari "Aldo Moro", Bari, Italy.
Andrea PiazzollaOrthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari "Aldo Moro", Bari, Italy.
Giovanni VicentiOrthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari "Aldo Moro", Bari, Italy.
Biagio MorettiOrthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari "Aldo Moro", Bari, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeto evaluate the differences in clinical outcome and survivorship of three different mobile bearings for total knee arthroplasty.

methodsa retrospective study was conducted in 60 patients (53 females, 7 males, mean age: 68 years and 5 months) each submitted to total knee replacement using one of the three different mobile bearings of the LCS system (Depuy Johnson & Johnson, Warsaw, IN). The diagnosis was knee osteoarthritis in 57 cases and rheumatoid arthritis in three cases. Three different groups of 20 cases each were identified: total knee arthroplasties with mobile menisci (group 1); total knee arthroplasties with the rotating platform (group 2); and total knee arthroplasties with the anteroposterior glide platform (group 3). As regards the component fixation, 33 implants were cementless, three were cemented, and in 24 only the tibial component was cemented. The patella was not replaced.

resultsalthough the duration of follow-up differed between the three groups, the clinical and radiological results at final follow-up showed no revision of femoral and/or tibial components for mechanical or septic reasons, and no signs of impending failure. One meniscal bearing, showing polyethylene wear after 17 years, was successfully replaced.

conclusionsthe present retrospective study confirmed the long-term effectiveness of knee implants with mobile bearings, in which the congruity of the surfaces makes it possible to overcome the problem of high contact stresses that may result in polyethylene wear and osteolysis; at the same time, these implants eliminate constraint forces thereby reducing the risk of mechanical loosening. LEVEL OF EVIDENCE: Level III, retrospective comparative study.

Indexed as

knee arthroplastymeniscal bearingsmobile bearingrotating platform

Identifiers

PMID25606553
PMCPMC4295681

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.