Evidence map›Paper›PMID 25599978›Full record

ArticleNeurogastroenterology and motility2015

Multi-channel wireless mapping of gastrointestinal serosal slow wave propagation.

N Paskaranandavadivel, R Wang, S Sathar, G O'Grady, L K Cheng, A Farajidavar

Open access · greenAbstract read
In one paragraph

Article in Neurogastroenterology and motility, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
9.1field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 36 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Gastric Seed: Towards Distributed Ultrasonically Interrogated Millimeter-Sized Implants for Large-Scale Gastric Electrical-Wave Recording.IEEE transactions on circuits and systems. II, Express briefs : a publication of the IEEE Circuits and Systems Society · 2019
    Article
  5. Article
  6. Article
  7. Article
  8. Time-Delay Mapping of High-Resolution Gastric Slow-Wave Activity.IEEE transactions on bio-medical engineering · 2017
    Article
  9. Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

N PaskaranandavadivelAuckland Bioengineering Institute, University of Auckland, Auckland, New Zealand.
R Wang
S Sathar
G O'Grady
L K Cheng
A Farajidavar
University of Auckland · NZNew York Institute of Technology · US

Funding

Realistic models of gastrointestinal bioelectromagnetismR01DK064775 · NIDDK · VANDERBILT UNIVERSITY MEDICAL CENTER · PI CHENG, LEO · 2004 to 2014
$2.6M
NIDDK NIH HHS R01 DK064775NIDDK NIH HHS R01 DK64775
6 · The paper itself

Abstract

backgroundHigh-resolution (HR) extracellular mapping allows accurate profiling of normal and dysrhythmic slow wave patterns. A current limitation is that cables traverse the abdominal wall or a natural orifice, risking discomfort, dislodgement or infection. Wireless approaches offer advantages, but a multi-channel system is required, capable of recording slow waves and mapping propagation with high fidelity.

methodsA novel multi-channel (n = 7) wireless mapping system was developed and compared to a wired commercial system. Slow wave signals were recorded from the porcine gastric and intestinal serosa in vivo. Signals were simultaneously acquired using both systems, and were filtered and processed to map activation wavefronts. For validation, the frequency and amplitude of detected events were compared, together with the speed and direction of mapped wavefronts. KEY

resultsThe wireless device achieved comparable signal quality to the reference device, and slow wave frequencies were identical. Amplitudes of the acquired gastric and intestinal slow wave signals were consistent between the devices. During normal propagation, spatiotemporal mapping remained accurate in the wireless system, however, during ectopic dysrhythmic pacemaking, the lower sampling resolution of the wireless device led to reduced accuracy in spatiotemporal mapping. CONCLUSIONS & INFERENCES: A novel multichannel wireless device is presented for mapping slow wave activity. The device achieved high quality signals, and has the potential to facilitate chronic monitoring studies and clinical translation of spatiotemporal mapping. The current implementation may be applied to detect normal patterns and dysrhythmia onset, but HR mapping with finely spaced arrays currently remains necessary to accurately define dysrhythmic patterns.

Indexed as

Wireless TechnologyAnimalsElectrodesElectrophysiological PhenomenaFemaleGastrointestinal MotilityStomachSwineTelemetrydysrhythmiagastric electrical activitywireless signal acquisition

Identifiers

PMID25599978
PMCPMC4380526
OpenAlexW2052919971

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.