ArticlePharmacognosy research
A novel reverse phase high-performance liquid chromatography method for standardization of Orthosiphon stamineus leaf extracts.
Article in Pharmacognosy research. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 1 synthesis or guideline pooled it.
- A Systematic Review ofMolecules (Basel, Switzerland) · 2022Pooled it
- Aldose Reductase Inhibition byMolecules (Basel, Switzerland) · 2025Article
- Article
- Article
- Mechanism of action ofSaudi pharmaceutical journal : SPJ : the official publication of the Saudi Pharmaceutical Society · 2022Article
- Therapeutic Effectiveness of Sinensetin Against Cancer and Other Human Complications: A Review of Biological Potential and Pharmacological Activities.Cardiovascular & hematological disorders drug targets · 2022Article
- Molecular docking analysis and anti-hyperglycaemic activity of Synacinn™ in streptozotocin-induced rats.RSC advances · 2020Article
- Assessment of a developed HPLC-MS/MS approach for determining plasma eupatorin in rats and its application in pharmacokinetics analysis.RSC advances · 2020Article
- Optimization of Ultrasound-Assisted Extraction Conditions Followed by Solid Phase Extraction Fractionation fromMolecules (Basel, Switzerland) · 2019Article
- Identification of Metabolites of Eupatorin in Vivo and in Vitro Based on UHPLC-Q-TOF-MS/MS.Molecules (Basel, Switzerland) · 2019Article
- Selected metabolites profiling of Orthosiphon stamineus Benth leaves extracts combined with chemometrics analysis and correlation with biological activities.BMC complementary and alternative medicine · 2015Article
- Review
- Article
- High-performance Thin-layer Chromatography Method Development, Validation, and Simultaneous Quantification of Four Compounds Identified in Standardized Extracts ofPharmacognosy researchArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundOrthosiphon stamineus Benth. (Lamiaceae) is a traditional medicinal plant which has been used in treating various ailments such as kidney diseases, bladder inflammation, arthritis and diabetes. The leaves contain high concentration of phenolic compounds, thus, rosmarinic acid (RA), 3'-hydroxy-5, 6, 7, 4'-tetramethoxyflavone (TMF), sinensetin (SIN) and eupatorin (EUP) were chosen as a marker compounds for standardization of various O. stamineus leaf extracts.
objectiveThe aim was to develop and validate a new high-performance liquid chromatography (HPLC) method for quantification of 4 marker compounds (RA, TMF, SIN, EUP) in various O. stamineus leaf extracts. MATERIALS AND
methodsThe method was developed and validated using RP-HPLC-diode-array detection at 320 nm for accuracy, precision and limits of detection and was applied for quantification of it markers in five different extracts prepared in solvents with increasing polarity, using a gradient mobile phase 0.1% formic acid: Acetonitrile at a flow rate of 1 ml/min on reverse phase acclaim polar advantage II C18 column (3 μm, 3 × 150 mm) with 18 min separation time.
resultsThe developed method provided satisfactory precision, and the accuracy of this method was in the range of 90.2% to 105.5%. All of 4 compounds showed good linearity at R2 > 0.999.
conclusionThe developed method is a simple, cost effective with shorter run time (18 min) in comparison to previous methods (30 min) and utilization of environmental-friendly solvents system. Therefore, this method has the potential to replace currently used methods in the routine standardization work of O. stamineus extracts, raw materials and its commercial products.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials